Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2009 |
Principal Product | Dermalogical pharmaceuticals |
NAICS | 325412 - Pharmaceutical Preparation Manufacturing |
SIC | 2834 - Pharmaceutical Preparations |
Sales | <$500,000 |
# of Employees | 66 |
Plant Area (Sq.Ft.) | 48,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 2,860 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $271,500 | 3,810,000 | kWh | $0.07 |
Electricity Demand | $110,240 | 7,530 | kW-months/year | $14.64 |
Natural Gas | $220,317 | 14,688 | MMBtu | $15.00 |
TOTAL ENERGY COSTS | $602,057 | |||
RECOMMENDED SAVINGS* | $53,407 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,760 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6122 ADJUST VENTS TO MINIMIZE ENERGY USE |
Savings: $4,936 Cost: - |
$1,260 | 17,685 | $380 | 26 | $3,296 | 220 |
$1,260 17,685 kWh |
$380 26 kW-months/year |
$3,296 220 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,697 Cost: - |
$80 | 1,124 | - | - | $2,617 | 175 |
$80 1,124 kWh |
- - kW-months/year |
$2,617 175 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,063 Cost: $500 |
$2,063 | 28,959 | - | - | - | - |
$2,063 28,959 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $396 Cost: $75 |
$213 | 2,995 | $183 | 9 | - | - |
$213 2,995 kWh |
$183 9 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $28,409 Cost: $12,868 |
$28,409 | 398,651 | - | - | - | - |
$28,409 398,651 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $13,576 Cost: $17,518 |
$8,523 | 119,605 | $5,053 | 346 | - | - |
$8,523 119,605 kWh |
$5,053 346 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $559 Cost: $840 |
$202 | 2,831 | $357 | 20 | - | - |
$202 2,831 kWh |
$357 20 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $771 Cost: $1,925 |
$372 | 5,219 | $399 | 27 | - | - |
$372 5,219 kWh |
$399 27 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $53,407 Cost: $33,726 |
$41,122 | 577,069 | $6,372 | 428 | $5,913 | 395 | $41,122 577,069 kWh |
$6,372 428 kW-months/year |
$5,913 395 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,760 Cost: $500 |
$2,143 | 30,083 | - | - | $2,617 | 175 | $2,143 30,083 kWh |
- - kW-months/year |
$2,617 175 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |