IAC logo
IAC Assessment: SF0378
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0378
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2009
Principal Product Dermalogical pharmaceuticals
NAICS 325412 - Pharmaceutical Preparation Manufacturing
SIC 2834 - Pharmaceutical Preparations
Sales <$500,000
# of Employees 66
Plant Area (Sq.Ft.) 48,000
Annual Production 1 Units
Production Hrs. Annual 2,860
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $271,500 3,810,000 kWh $0.07
Electricity Demand $110,240 7,530 kW-months/year $14.64
Natural Gas $220,317 14,688 MMBtu $15.00
TOTAL ENERGY COSTS $602,057
RECOMMENDED SAVINGS* $53,407 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,760
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.6122 ADJUST VENTS TO MINIMIZE ENERGY USE Savings:
$4,936
Cost:
-
$1,260 17,685 $380 26 $3,296 220 $1,260
17,685
kWh
$380
26
kW-months/year
$3,296
220
MMBtu
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$2,697
Cost:
-
$80 1,124 - - $2,617 175 $80
1,124
kWh
-
-
kW-months/year
$2,617
175
MMBtu
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$2,063
Cost:
$500
$2,063 28,959 - - - - $2,063
28,959
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$396
Cost:
$75
$213 2,995 $183 9 - - $213
2,995
kWh
$183
9
kW-months/year
-
-
MMBtu
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$28,409
Cost:
$12,868
$28,409 398,651 - - - - $28,409
398,651
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$13,576
Cost:
$17,518
$8,523 119,605 $5,053 346 - - $8,523
119,605
kWh
$5,053
346
kW-months/year
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$559
Cost:
$840
$202 2,831 $357 20 - - $202
2,831
kWh
$357
20
kW-months/year
-
-
MMBtu
08: 2.7134 USE PHOTOCELL CONTROLS Savings:
$771
Cost:
$1,925
$372 5,219 $399 27 - - $372
5,219
kWh
$399
27
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$53,407
Cost:
$33,726
$41,122 577,069 $6,372 428 $5,913 395 $41,122
577,069
kWh
$6,372
428
kW-months/year
$5,913
395
MMBtu
TOTAL IMPLEMENTED Savings:
$4,760
Cost:
$500
$2,143 30,083 - - $2,617 175 $2,143
30,083
kWh
-
-
kW-months/year
$2,617
175
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas