Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2011 |
Principal Product | Liquid Milk |
NAICS | 311511 - Fluid Milk Manufacturing |
SIC | 2026 - Fluid Milk |
Sales | $10,000,000-$50,000,000 |
# of Employees | 385 |
Plant Area (Sq.Ft.) | 41,000 |
Annual Production | 22,000 Thousand Gallons |
Production Hrs. Annual | 8,112 |
Location (State) | HI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,035,721 | 5,895,486 | kWh | $0.18 |
Electricity Demand | $166,405 | 12,373 | kW-months/year | $13.45 |
Electricity Fees | $26,736 | - | $ | - |
Natural Gas | $314,339 | 13,907 | MMBtu | $22.60 |
TOTAL ENERGY COSTS | $1,543,201 | |||
RECOMMENDED SAVINGS* | $328,667 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $163,858 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,408 Cost: $720 |
$7,408 | 42,164 | - | - | - | - |
$7,408 42,164 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $99,396 Cost: $33,822 |
- | - | - | - | $99,396 | 4,398 |
- - kWh |
- - kW-months/year |
$99,396 4,398 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,385 Cost: $4,330 |
$6,385 | 36,343 | - | - | - | - |
$6,385 36,343 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,791 Cost: $1,329 |
$1,791 | 10,195 | - | - | - | - |
$1,791 10,195 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $153,800 Cost: $220,659 |
$132,585 | 756,163 | $21,215 | 1,560 | - | - |
$132,585 756,163 kWh |
$21,215 1,560 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $9,218 Cost: $19,157 |
$9,218 | 52,467 | - | - | - | - |
$9,218 52,467 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $32,171 Cost: $34,310 |
- | - | - | - | $32,171 | 1,423 |
- - kWh |
- - kW-months/year |
$32,171 1,423 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $6,132 Cost: $17,178 |
- | - | - | - | $6,132 | 271 |
- - kWh |
- - kW-months/year |
$6,132 271 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,350 Cost: $25,921 |
$9,350 | 37,450 | - | - | - | - |
$9,350 37,450 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,016 Cost: $14,478 |
$3,016 | 13,890 | - | - | - | - |
$3,016 13,890 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $328,667 Cost: $371,904 |
$169,753 | 948,672 | $21,215 | 1,560 | $137,699 | 6,092 | $169,753 948,672 kWh |
$21,215 1,560 kW-months/year |
$137,699 6,092 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $163,858 Cost: $130,759 |
$26,159 | 129,847 | - | - | $137,699 | 6,092 | $26,159 129,847 kWh |
- - kW-months/year |
$137,699 6,092 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |