Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2012 |
Principal Product | Treated Water |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | <$500,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 1,700,000 |
Annual Production | 12,000,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $965,684 | 13,059,828 | kWh | $0.07 |
Electricity Demand | $536,086 | 27,952 | kW-months/year | $19.18 |
Electricity Fees | $64,950 | - | $ | - |
Natural Gas | $189,772 | 30,727 | MMBtu | $6.18 |
TOTAL ENERGY COSTS | $1,756,492 | |||
RECOMMENDED SAVINGS* | $376,998 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $293,740 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $77,652 Cost: $5,000 |
$56,271 | 762,482 | $21,381 | 1,044 | - | - | - | - |
$56,271 762,482 kWh |
$21,381 1,044 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $18,634 Cost: $8,163 |
$13,498 | 182,896 | $5,136 | 251 | - | - | - | - |
$13,498 182,896 kWh |
$5,136 251 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $136,139 Cost: $189,204 |
$102,961 | 1,383,282 | $33,178 | 1,895 | - | - | - | - |
$102,961 1,383,282 kWh |
$33,178 1,895 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $5,606 Cost: $11,795 |
$5,606 | 75,958 | - | - | - | - | - | - |
$5,606 75,958 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,106 Cost: $10,756 |
$2,163 | 29,278 | $943 | 65 | - | - | - | - |
$2,163 29,278 kWh |
$943 65 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,582 Cost: $28,175 |
$4,985 | 67,002 | $1,597 | 91 | - | - | - | - |
$4,985 67,002 kWh |
$1,597 91 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $12,835 Cost: $60,972 |
$8,319 | 111,995 | $4,516 | 250 | - | - | - | - |
$8,319 111,995 kWh |
$4,516 250 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $21,277 Cost: $149,347 |
- | - | - | - | - | - | $21,277 | 3,449 |
- - kWh |
- - kW-months/year |
- - $ |
$21,277 3,449 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $95,167 Cost: - |
- | - | - | - | $95,167 | - | - | - |
- - kWh |
- - kW-months/year |
$95,167 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $376,998 Cost: $463,412 |
$193,803 | 2,612,893 | $66,751 | 3,595 | $95,167 | - | $21,277 | 3,449 | $193,803 2,612,893 kWh |
$66,751 3,595 kW-months/year |
$95,167 - $ |
$21,277 3,449 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $293,740 Cost: $446,617 |
$131,926 | 1,774,453 | $45,370 | 2,551 | $95,167 | - | $21,277 | 3,449 | $131,926 1,774,453 kWh |
$45,370 2,551 kW-months/year |
$95,167 - $ |
$21,277 3,449 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |