Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2014 |
Principal Product | Plastic Containers |
NAICS | 326121 - Unlaminated Plastics Profile Shape Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 77 |
Plant Area (Sq.Ft.) | 137,500 |
Annual Production | 10,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $718,706 | 8,555,049 | kWh | $0.08 |
Electricity Demand | $363,447 | 16,824 | kW-months/year | $21.60 |
Natural Gas | $1,627 | 168 | MMBtu | $9.71 |
TOTAL ENERGY COSTS | $1,083,780 | |||
RECOMMENDED SAVINGS* | $227,253 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,614 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $10,814 Cost: $70 |
$7,997 | 95,024 | $2,817 | 131 | - | - | - | - | - | - |
$7,997 95,024 kWh |
$2,817 131 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $4,248 Cost: - |
$4,248 | 50,570 | - | - | - | - | - | - | - | - |
$4,248 50,570 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $5,366 Cost: $4,235 |
$3,968 | 47,232 | $1,398 | 65 | - | - | - | - | - | - |
$3,968 47,232 kWh |
$1,398 65 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $38,158 Cost: $105,000 |
- | - | - | - | $38,158 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$38,158 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,240 Cost: $6,743 |
$1,163 | 13,848 | $1,077 | 50 | - | - | - | - | - | - |
$1,163 13,848 kWh |
$1,077 50 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $23,962 Cost: $93,924 |
$23,962 | 285,257 | - | - | - | - | - | - | - | - |
$23,962 285,257 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,341 Cost: $15,131 |
$2,958 | 35,217 | - | - | - | - | $66 | - | $317 | - |
$2,958 35,217 kWh |
- - kW-months/year |
- - $ |
$66 - $ |
$317 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $139,124 Cost: $745,024 |
$57,649 | 479,812 | $81,475 | 3,329 | - | - | - | - | - | - |
$57,649 479,812 kWh |
$81,475 3,329 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $227,253 Cost: $970,127 |
$101,945 | 1,006,960 | $86,767 | 3,575 | $38,158 | - | $66 | - | $317 | - | $101,945 1,006,960 kWh |
$86,767 3,575 kW-months/year |
$38,158 - $ |
$66 - $ |
$317 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,614 Cost: $4,235 |
$8,216 | 97,802 | $1,398 | 65 | - | - | - | - | - | - | $8,216 97,802 kWh |
$1,398 65 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Ancillary Material Cost |