Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2014 |
Principal Product | Ophthalmic Equipment |
NAICS | 333314 - Optical Instrument and Lens Manufacturing |
SIC | 3827 - Optical Instruments And Lenses |
Sales | $10,000,000-$50,000,000 |
# of Employees | 720 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 5 Units |
Production Hrs. Annual | 2,600 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $188,873 | 2,524,403 | kWh | $0.07 |
Electricity Demand | $104,412 | 5,851 | kW-months/year | $17.85 |
Natural Gas | $20,517 | 2,317 | MMBtu | $8.86 |
TOTAL ENERGY COSTS | $313,802 | |||
RECOMMENDED SAVINGS* | $56,008 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,290 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $660 Cost: $280 |
$398 | 3,177 | $262 | 15 | - | - |
$398 3,177 kWh |
$262 15 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $10,804 Cost: $9,262 |
$3,549 | 28,314 | $8,354 | 468 | $(-1,099) | - |
$3,549 28,314 kWh |
$8,354 468 kW-months/year |
$(-1,099) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $317 Cost: $307 |
$317 | 2,529 | - | - | - | - |
$317 2,529 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $28,600 Cost: $42,672 |
$18,248 | 145,564 | $10,352 | 580 | - | - |
$18,248 145,564 kWh |
$10,352 580 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,630 Cost: $27,842 |
$3,274 | 26,114 | - | - | $9,356 | - |
$3,274 26,114 kWh |
- - kW-months/year |
$9,356 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,997 Cost: $14,024 |
$1,819 | 14,511 | $1,178 | 66 | - | - |
$1,819 14,511 kWh |
$1,178 66 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $56,008 Cost: $94,387 |
$27,605 | 220,209 | $20,146 | 1,128 | $8,257 | - | $27,605 220,209 kWh |
$20,146 1,128 kW-months/year |
$8,257 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,290 Cost: $28,122 |
$3,672 | 29,291 | $262 | 15 | $9,356 | - | $3,672 29,291 kWh |
$262 15 kW-months/year |
$9,356 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |