Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2015 |
Principal Product | Pre-Engineered Metal Buildings |
NAICS | 332311 - Prefabricated Metal Building and Component Manufacturing |
SIC | 3448 - Prefabricated Metal Buildings |
Sales | $50,000,000-$100,000,000 |
# of Employees | 157 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 16,500 Tons |
Production Hrs. Annual | 6,884 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $186,867 | 1,284,226 | kWh | $0.15 |
Electricity Demand | $52,330 | 4,277 | kW-months/year | $12.24 |
Electricity Fees | $2,060 | - | $ | - |
Natural Gas | $726 | 53 | MMBtu | $13.76 |
TOTAL ENERGY COSTS | $241,985 | |||
RECOMMENDED SAVINGS* | $173,347 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $161,559 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $7,057 Cost: - |
$6,866 | 47,188 | - | - | $191 | 14 | - | - | - | - |
$6,866 47,188 kWh |
- - kW-months/year |
$191 14 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,181 Cost: - |
$2,709 | 18,616 | - | - | - | - | $(-528) | - | - | - |
$2,709 18,616 kWh |
- - kW-months/year |
- - MMBtu |
$(-528) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,523 Cost: $66 |
$1,311 | 9,011 | $212 | 17 | - | - | - | - | - | - |
$1,311 9,011 kWh |
$212 17 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $951 Cost: $144 |
$951 | 6,538 | - | - | - | - | - | - | - | - |
$951 6,538 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,208 Cost: $2,648 |
$2,224 | 15,284 | $984 | 80 | - | - | - | - | - | - |
$2,224 15,284 kWh |
$984 80 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $10,962 Cost: $10,585 |
$10,962 | 75,337 | - | - | - | - | - | - | - | - |
$10,962 75,337 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $24,885 Cost: $76,232 |
$25,209 | 173,243 | $3,191 | 260 | - | - | $418 | - | $(-3,933) | - |
$25,209 173,243 kWh |
$3,191 260 kW-months/year |
- - MMBtu |
$418 - $ |
$(-3,933) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $121,903 Cost: $1,110,964 |
$121,903 | 837,763 | - | - | - | - | - | - | - | - |
$121,903 837,763 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $677 Cost: - |
- | - | - | - | - | - | $677 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$677 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $173,347 Cost: $1,200,639 |
$172,135 | 1,182,980 | $4,387 | 358 | $191 | 14 | $567 | - | $(-3,933) | - | $172,135 1,182,980 kWh |
$4,387 358 kW-months/year |
$191 14 MMBtu |
$567 - $ |
$(-3,933) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $161,559 Cost: $1,197,925 |
$161,734 | 1,111,497 | $3,191 | 260 | - | - | $567 | - | $(-3,933) | - | $161,734 1,111,497 kWh |
$3,191 260 kW-months/year |
- - MMBtu |
$567 - $ |
$(-3,933) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost |