Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2016
Principal Product Vehicle Suspension Products
NAICS 336330 - Motor Vehicle Steering and Suspension Components (except Spring) Manufacturing
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $10,000,000-$50,000,000
# of Employees 300
Plant Area (Sq.Ft.) 86,000
Annual Production 43,000 Pieces
Production Hrs. Annual 5,520
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $144,016 1,338,938 kWh $0.11
Electricity Demand $92,623 3,528 kW-months/year $26.25
Natural Gas $25,087 2,632 MMBtu $9.53
TOTAL ENERGY COSTS $261,726
RECOMMENDED SAVINGS* $158,803 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $84,035
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$81,971
Cost:
-
$79,052 734,954 - - $2,919 307 - - - - $79,052
734,954
kWh
-
-
kW-months/year
$2,919
307
MMBtu
-
-
$
-
-
$
02: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$2,064
Cost:
$1,350
- - - - $2,064 217 - - - - -
-
kWh
-
-
kW-months/year
$2,064
217
MMBtu
-
-
$
-
-
$
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,216
Cost:
$1,134
$819 7,613 $397 15 - - - - - - $819
7,613
kWh
$397
15
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,058
Cost:
$8,198
$5,045 46,903 $3,324 126 - - $113 - $(-424) - $5,045
46,903
kWh
$3,324
126
kW-months/year
-
-
MMBtu
$113
-
$
$(-424)
-
$
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$65,494
Cost:
$424,736
$40,129 373,088 $25,365 965 - - - - - - $40,129
373,088
kWh
$25,365
965
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$158,803
Cost:
$435,418
$125,045 1,162,558 $29,086 1,106 $4,983 524 $113 - $(-424) - $125,045
1,162,558
kWh
$29,086
1,106
kW-months/year
$4,983
524
MMBtu
$113
-
$
$(-424)
-
$
TOTAL IMPLEMENTED Savings:
$84,035
Cost:
$1,350
$79,052 734,954 - - $4,983 524 - - - - $79,052
734,954
kWh
-
-
kW-months/year
$4,983
524
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost