Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2017 |
Principal Product | Biodiesel |
NAICS | 324110 - Petroleum Refineries |
SIC | 2911 - Petroleum Refining |
Sales | $10,000,000-$50,000,000 |
# of Employees | 17 |
Plant Area (Sq.Ft.) | 140,000 |
Annual Production | 8,000 Thousand Gallons |
Production Hrs. Annual | 6,240 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $407,495 | 2,670,602 | kWh | $0.15 |
Electricity Demand | $37,644 | 8,448 | kW-months/year | $4.46 |
Natural Gas | $279,412 | 38,086 | MMBtu | $7.34 |
TOTAL ENERGY COSTS | $724,551 | |||
RECOMMENDED SAVINGS* | $85,563 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,897 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $23,294 Cost: $4,639 |
$23,294 | 154,429 | - | - | - | - | - | - | - | - |
$23,294 154,429 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $486 Cost: $86 |
$458 | 3,036 | $28 | 6 | - | - | - | - | - | - |
$458 3,036 kWh |
$28 6 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $7,070 Cost: $1,651 |
$6,657 | 44,135 | $413 | 85 | - | - | - | - | - | - |
$6,657 44,135 kWh |
$413 85 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $14,325 Cost: $6,323 |
$14,325 | 94,968 | - | - | - | - | - | - | - | - |
$14,325 94,968 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $8,816 Cost: $6,103 |
$8,816 | 58,444 | - | - | - | - | - | - | - | - |
$8,816 58,444 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $26,675 Cost: $28,219 |
$23,621 | 156,598 | $1,954 | 401 | - | - | $1,021 | - | $79 | - |
$23,621 156,598 kWh |
$1,954 401 kW-months/year |
- - MMBtu |
$1,021 - $ |
$79 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,828 Cost: $5,423 |
- | - | - | - | $3,828 | 522 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,828 522 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,069 Cost: $1,882 |
$1,069 | 7,087 | - | - | - | - | - | - | - | - |
$1,069 7,087 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $85,563 Cost: $54,326 |
$78,240 | 518,697 | $2,395 | 492 | $3,828 | 522 | $1,021 | - | $79 | - | $78,240 518,697 kWh |
$2,395 492 kW-months/year |
$3,828 522 MMBtu |
$1,021 - $ |
$79 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,897 Cost: $7,305 |
$1,069 | 7,087 | - | - | $3,828 | 522 | - | - | - | - | $1,069 7,087 kWh |
- - kW-months/year |
$3,828 522 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||