Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2017
Principal Product Finished Wines
NAICS 312130 - Wineries
SIC 2084 - Wines, Brandy, And Brandy Spirits
Sales $100,000,000-$500,000,000
# of Employees 100
Plant Area (Sq.Ft.) 600,000
Annual Production 18,500 Thousand Gallons
Production Hrs. Annual 6,408
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $569,139 6,591,372 kWh $0.09
Electricity Demand $388,859 21,132 kW-months/year $18.40
Natural Gas $21,807 1,886 MMBtu $11.57
TOTAL ENERGY COSTS $979,805
RECOMMENDED SAVINGS* $197,836 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $197,836
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,318
Cost:
-
$3,990 46,211 - - - - $(-672) - - - $3,990
46,211
kWh
-
-
kW-months/year
-
-
MMBtu
$(-672)
-
$
-
-
$
02: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE Savings:
$7,895
Cost:
$560
$8,455 97,917 - - - - $(-560) - - - $8,455
97,917
kWh
-
-
kW-months/year
-
-
MMBtu
$(-560)
-
$
-
-
$
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$1,567
Cost:
$156
$1,567 18,148 - - - - - - - - $1,567
18,148
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$8,398
Cost:
$3,902
$604 6,996 - - $7,794 674 - - - - $604
6,996
kWh
-
-
kW-months/year
$7,794
674
MMBtu
-
-
$
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$116,456
Cost:
$172,681
$63,450 734,805 $31,858 1,728 - - $22,714 - $(-1,566) - $63,450
734,805
kWh
$31,858
1,728
kW-months/year
-
-
MMBtu
$22,714
-
$
$(-1,566)
-
$
06: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$5,369
Cost:
$12,526
$6,085 70,467 $2,761 150 $(-3,477) (-301) - - - - $6,085
70,467
kWh
$2,761
150
kW-months/year
$(-3,477)
(-301)
MMBtu
-
-
$
-
-
$
07: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$54,833
Cost:
$312,470
$54,833 635,003 - - - - - - - - $54,833
635,003
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$197,836
Cost:
$502,295
$138,984 1,609,547 $34,619 1,878 $4,317 373 $21,482 - $(-1,566) - $138,984
1,609,547
kWh
$34,619
1,878
kW-months/year
$4,317
373
MMBtu
$21,482
-
$
$(-1,566)
-
$
TOTAL IMPLEMENTED Savings:
$197,836
Cost:
$502,295
$138,984 1,609,547 $34,619 1,878 $4,317 373 $21,482 - $(-1,566) - $138,984
1,609,547
kWh
$34,619
1,878
kW-months/year
$4,317
373
MMBtu
$21,482
-
$
$(-1,566)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost