Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2018 |
Principal Product | Glassware |
NAICS | 327212 - Other Pressed and Blown Glass and Glassware Manufacturing |
SIC | 3229 - Pressed And Blown Glass, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 14 |
Plant Area (Sq.Ft.) | 7,500 |
Annual Production | 71,000 Units |
Production Hrs. Annual | 8,688 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $20,114 | 119,094 | kWh | $0.17 |
Electricity Demand | $10,504 | 571 | kW-months/year | $18.39 |
Natural Gas | $64,644 | 6,431 | MMBtu | $10.05 |
TOTAL ENERGY COSTS | $95,262 | |||
RECOMMENDED SAVINGS* | $49,803 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING |
Savings: $13,874 Cost: $3,023 |
- | - | - | - | $13,874 | 1,380 | - | - | - | - |
- - kWh |
- - kW-months/year |
$13,874 1,380 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $8,220 Cost: $4,857 |
$7,471 | 44,234 | $749 | 41 | - | - | - | - | - | - |
$7,471 44,234 kWh |
$749 41 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $17,611 Cost: $15,000 |
- | - | - | - | $17,611 | 1,752 | - | - | - | - |
- - kWh |
- - kW-months/year |
$17,611 1,752 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,777 Cost: $2,300 |
$1,070 | 6,337 | $472 | 25 | - | - | $99 | - | $136 | - |
$1,070 6,337 kWh |
$472 25 kW-months/year |
- - MMBtu |
$99 - $ |
$136 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1122 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT |
Savings: $2,098 Cost: $6,325 |
- | - | - | - | $2,098 | 209 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,098 209 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $6,223 Cost: $45,702 |
$6,223 | 36,844 | - | - | - | - | - | - | - | - |
$6,223 36,844 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $49,803 Cost: $77,207 |
$14,764 | 87,415 | $1,221 | 66 | $33,583 | 3,341 | $99 | - | $136 | - | $14,764 87,415 kWh |
$1,221 66 kW-months/year |
$33,583 3,341 MMBtu |
$99 - $ |
$136 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |