Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2019 |
Principal Product | wine |
NAICS | 312130 - Wineries |
SIC | 2084 - Wines, Brandy, And Brandy Spirits |
Sales | $100,000,000-$500,000,000 |
# of Employees | 177 |
Plant Area (Sq.Ft.) | 552,017 |
Annual Production | 12,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $502,026 | 4,332,924 | kWh | $0.12 |
Electricity Demand | $345,666 | 11,681 | kW-months/year | $29.59 |
Natural Gas | $118,471 | 15,832 | MMBtu | $7.48 |
TOTAL ENERGY COSTS | $966,163 | |||
RECOMMENDED SAVINGS* | $173,620 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $133,624 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $10,552 Cost: - |
- | - | - | - | $10,552 | 1,410 | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,552 1,410 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $5,167 Cost: $1,440 |
$5,167 | 48,927 | - | - | - | - | - | - | - | - |
$5,167 48,927 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $39,996 Cost: $12,500 |
$39,996 | 378,754 | - | - | - | - | - | - | - | - |
$39,996 378,754 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $15,254 Cost: $4,129 |
$10,712 | 101,436 | $4,542 | 139 | - | - | - | - | - | - |
$10,712 101,436 kWh |
$4,542 139 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,489 Cost: $4,651 |
$8,770 | 83,045 | $3,719 | 114 | - | - | - | - | - | - |
$8,770 83,045 kWh |
$3,719 114 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $5,888 Cost: $3,120 |
$4,191 | 39,685 | $1,697 | 52 | - | - | - | - | - | - |
$4,191 39,685 kWh |
$1,697 52 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $292 Cost: $163 |
$203 | 1,921 | $89 | 3 | - | - | - | - | - | - |
$203 1,921 kWh |
$89 3 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $36,088 Cost: $25,965 |
$33,067 | 191,549 | $3,021 | 307 | - | - | - | - | - | - |
$33,067 191,549 kWh |
$3,021 307 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $2,925 Cost: $3,138 |
$2,925 | 27,700 | - | - | - | - | - | - | - | - |
$2,925 27,700 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,765 Cost: $2,729 |
$1,180 | 11,172 | $585 | 18 | - | - | - | - | - | - |
$1,180 11,172 kWh |
$585 18 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,111 Cost: $11,016 |
$6,111 | 57,871 | - | - | - | - | - | - | - | - |
$6,111 57,871 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $37,093 Cost: $93,629 |
$24,183 | 229,007 | $10,299 | 315 | - | - | $2,321 | - | $290 | - |
$24,183 229,007 kWh |
$10,299 315 kW-months/year |
- - MMBtu |
$2,321 - $ |
$290 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $173,620 Cost: $162,480 |
$136,505 | 1,171,067 | $23,952 | 948 | $10,552 | 1,410 | $2,321 | - | $290 | - | $136,505 1,171,067 kWh |
$23,952 948 kW-months/year |
$10,552 1,410 MMBtu |
$2,321 - $ |
$290 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $133,624 Cost: $149,980 |
$96,509 | 792,313 | $23,952 | 948 | $10,552 | 1,410 | $2,321 | - | $290 | - | $96,509 792,313 kWh |
$23,952 948 kW-months/year |
$10,552 1,410 MMBtu |
$2,321 - $ |
$290 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |