IAC Center San Francisco State University
Assessment Year 2019
Principal Product Metal Parts
NAICS 332710 - Machine Shops
SIC 3599 - Industrial Machinery, Nec
Sales $2,800,000
# of Employees 20
Plant Area (Sq.Ft.) 10,000
Annual Production 120,000 not found
Production Hrs. Annual 3,250
Location (State) CA
Source Yearly Cost Usage
Electricity Usage $53,000 329,310
Electricity Demand $20,081 1,320
Natural Gas $1,825 141
TOTAL ENERGY COSTS $74,906
RECOMMENDED SAVINGS* $26,673 *Non-energy impacts
included in savings.
IMPLEMENTED SAVINGS* -
#|Description Status Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost
$ kWh $ kW/month $ $ $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,145
Cost:
-
$3,465 21,529 - - $(-1,320) - - - $3,465
21,529
kWh
-
-
kW/month
$(-1,320)
-
$
-
-
$
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$341
Cost:
$220
$302 1,878 $39 3 - - - - $302
1,878
kWh
$39
3
kW/month
-
-
$
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,832
Cost:
$7,129
$2,525 15,650 $893 56 $442 - $(-28) - $2,525
15,650
kWh
$893
56
kW/month
$442
-
$
$(-28)
-
$
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$20,355
Cost:
$80,550
$17,127 106,420 $3,228 212 - - - - $17,127
106,420
kWh
$3,228
212
kW/month
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$26,673
Cost:
$87,899
$23,419 145,477 $4,160 271 $(-878) - $(-28) - $23,419
145,477
kWh
$4,160
271
kW/month
$(-878)
-
$
$(-28)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW/month
-
-
$
-
-
$
$ kWh $ kW/month $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost
Back to Top