Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2020 |
Principal Product | Beer |
NAICS | 312120 - Breweries |
SIC | 2082 - Malt Beverages |
Sales | $5,000,000-$10,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 25,700 |
Annual Production | 3,500,000 Units |
Production Hrs. Annual | 4,914 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $60,551 | 532,522 | kWh | $0.11 |
Electricity Demand | $50,859 | 1,505 | kW-months/year | $33.79 |
Natural Gas | $16,032 | 1,349 | MMBtu | $11.88 |
TOTAL ENERGY COSTS | $127,442 | |||
RECOMMENDED SAVINGS* | $24,309 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $24,309 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,782 Cost: $1,359 |
$4,782 | 42,054 | - | - | - | - | - | - | - | - |
$4,782 42,054 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,259 Cost: $787 |
- | - | - | - | $1,259 | 106 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,259 106 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,899 Cost: $4,002 |
$3,899 | 34,289 | - | - | - | - | - | - | - | - |
$3,899 34,289 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,809 Cost: $17,557 |
$5,924 | 52,096 | $5,320 | 157 | - | - | $601 | - | $(-36) | - |
$5,924 52,096 kWh |
$5,320 157 kW-months/year |
- - MMBtu |
$601 - $ |
$(-36) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,560 Cost: $12,365 |
$2,560 | 22,507 | - | - | - | - | - | - | - | - |
$2,560 22,507 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $24,309 Cost: $36,070 |
$17,165 | 150,946 | $5,320 | 157 | $1,259 | 106 | $601 | - | $(-36) | - | $17,165 150,946 kWh |
$5,320 157 kW-months/year |
$1,259 106 MMBtu |
$601 - $ |
$(-36) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $24,309 Cost: $36,070 |
$17,165 | 150,946 | $5,320 | 157 | $1,259 | 106 | $601 | - | $(-36) | - | $17,165 150,946 kWh |
$5,320 157 kW-months/year |
$1,259 106 MMBtu |
$601 - $ |
$(-36) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |