Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2021
Principal Product Still Wines
NAICS 312130 - Wineries
SIC 2084 - Wines, Brandy, And Brandy Spirits
Sales $1,000,000-$5,000,000
# of Employees 16
Plant Area (Sq.Ft.) 67,500
Annual Production 67 Thousand Gallons
Production Hrs. Annual 3,200
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $153,292 978,433 kWh $0.16
Electricity Demand $24,220 2,151 kW-months/year $11.26
Electricity Fees $32,933 - $ -
LPG $34,503 2,631 MMBtu $13.11
TOTAL ENERGY COSTS $244,948
RECOMMENDED SAVINGS* $277,371 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $277,371
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Primary Product Electricity Usage Electricity Demand Primary Product
$ kWh $ kW-months/year $ $
01: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE Savings:
$5,931
Cost:
-
$5,931 35,285 - - - - $5,931
35,285
kWh
-
-
kW-months/year
-
-
$
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$4,698
Cost:
$3,740
$4,698 27,945 - - - - $4,698
27,945
kWh
-
-
kW-months/year
-
-
$
03: 2.2691 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS Savings:
$5,693
Cost:
$9,138
$5,693 33,866 - - - - $5,693
33,866
kWh
-
-
kW-months/year
-
-
$
04: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$7,674
Cost:
$23,650
$7,674 45,651 - - - - $7,674
45,651
kWh
-
-
kW-months/year
-
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,279
Cost:
$6,956
$2,279 13,559 - - - - $2,279
13,559
kWh
-
-
kW-months/year
-
-
$
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$107,546
Cost:
$722,227
$104,851 832,207 $2,695 188 - - $104,851
832,207
kWh
$2,695
188
kW-months/year
-
-
$
07: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS Savings:
$143,550
Cost:
$77,720
- - - - $143,550 - -
-
kWh
-
-
kW-months/year
$143,550
-
$
TOTAL RECOMMENDED Savings:
$277,371
Cost:
$843,431
$131,126 988,513 $2,695 188 $143,550 - $131,126
988,513
kWh
$2,695
188
kW-months/year
$143,550
-
$
TOTAL IMPLEMENTED Savings:
$277,371
Cost:
$843,431
$131,126 988,513 $2,695 188 $143,550 - $131,126
988,513
kWh
$2,695
188
kW-months/year
$143,550
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Primary Product Electricity Usage Electricity Demand Primary Product