IAC Center | San Francisco State University |
---|---|
Assessment Year | 2021 |
Principal Product | Still Wines |
NAICS | 312130 - Wineries |
SIC | 2084 - Wines, Brandy, And Brandy Spirits |
Sales | >$500,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 510,000 |
Annual Production | 12,800 Thousand Gallons |
Production Hrs. Annual | 4,160 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,323,479 | 9,946,685 | kWh | $0.13 |
Electricity Demand | $197,497 | 9,996 | kW-months/year | $19.76 |
Natural Gas | $145,807 | 13,277 | MMBtu | $10.98 |
TOTAL ENERGY COSTS | $1,732,899 | |||
RECOMMENDED SAVINGS* | $611,471 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $456,455 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS |
Savings: $24,674 Cost: - |
$24,674 | 133,302 | - | - | - | - | - | - |
$24,674 133,302 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $27,893 Cost: - |
$27,893 | 157,176 | - | - | - | - | - | - |
$27,893 157,176 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2691 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS |
Savings: $149,399 Cost: $10,195 |
$149,399 | 807,124 | - | - | - | - | - | - |
$149,399 807,124 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $71,549 Cost: $5,641 |
$38,815 | 209,697 | - | - | $32,734 | 2,981 | - | - |
$38,815 209,697 kWh |
- - kW-months/year |
$32,734 2,981 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $106,544 Cost: $31,500 |
$106,544 | 575,606 | - | - | - | - | - | - |
$106,544 575,606 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $514 Cost: $190 |
$448 | 2,422 | $66 | 3 | - | - | - | - |
$448 2,422 kWh |
$66 3 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $39,174 Cost: $48,150 |
$39,174 | 211,636 | - | - | - | - | - | - |
$39,174 211,636 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,387 Cost: $6,315 |
$3,387 | 18,400 | - | - | - | - | - | - |
$3,387 18,400 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $291 Cost: $648 |
$291 | 1,571 | - | - | - | - | - | - |
$291 1,571 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,784 Cost: $27,535 |
$5,546 | 29,962 | $1,305 | 66 | - | - | $1,933 | - |
$5,546 29,962 kWh |
$1,305 66 kW-months/year |
- - MMBtu |
$1,933 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $179,262 Cost: $1,269,472 |
$175,657 | 1,612,267 | $3,605 | 84 | - | - | - | - |
$175,657 1,612,267 kWh |
$3,605 84 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $611,471 Cost: $1,399,646 |
$571,828 | 3,759,163 | $4,976 | 153 | $32,734 | 2,981 | $1,933 | - | $571,828 3,759,163 kWh |
$4,976 153 kW-months/year |
$32,734 2,981 MMBtu |
$1,933 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $456,455 Cost: $1,292,271 |
$420,116 | 2,939,537 | $3,605 | 84 | $32,734 | 2,981 | - | - | $420,116 2,939,537 kWh |
$3,605 84 kW-months/year |
$32,734 2,981 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |