Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2022 |
Principal Product | Wire and Cable |
NAICS | 335929 - Other Communication and Energy Wire Manufacturing |
SIC | 3357 - Nonferrous Wiredrawing & Insulating |
Sales | $50,000,000-$100,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 136,000 |
Annual Production | 21,000 Thousand Feet |
Production Hrs. Annual | 7,344 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $828,478 | 9,327,830 | kWh | $0.09 |
Electricity Demand | $391,152 | 17,316 | kW-months/year | $22.59 |
Electricity Fees | $17,966 | - | $ | - |
Natural Gas | $147,294 | 9,712 | MMBtu | $15.17 |
TOTAL ENERGY COSTS | $1,384,890 | |||
RECOMMENDED SAVINGS* | $192,977 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $192,977 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,887 Cost: - |
$1,887 | 21,325 | - | - | - | - | - | - |
$1,887 21,325 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $10,868 Cost: - |
$11,948 | 134,544 | - | - | $(-1,080) | - | - | - |
$11,948 134,544 kWh |
- - kW-months/year |
$(-1,080) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $38,078 Cost: $22,361 |
$38,078 | 428,802 | - | - | - | - | - | - |
$38,078 428,802 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $38,428 Cost: $26,487 |
$24,142 | 271,863 | $13,488 | 598 | $869 | - | $(-71) | - |
$24,142 271,863 kWh |
$13,488 598 kW-months/year |
$869 - $ |
$(-71) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $35,916 Cost: $68,135 |
$35,916 | 404,465 | - | - | - | - | - | - |
$35,916 404,465 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,974 Cost: $4,260 |
$1,974 | 22,228 | - | - | - | - | - | - |
$1,974 22,228 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,736 Cost: $14,830 |
$3,736 | 42,077 | - | - | - | - | - | - |
$3,736 42,077 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3311 REPLACE DC EQUIPMENT WITH AC EQUIPMENT |
Savings: $62,090 Cost: $317,631 |
$43,874 | 494,080 | $18,216 | 806 | - | - | - | - |
$43,874 494,080 kWh |
$18,216 806 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $192,977 Cost: $453,704 |
$161,555 | 1,819,384 | $31,704 | 1,404 | $(-211) | - | $(-71) | - | $161,555 1,819,384 kWh |
$31,704 1,404 kW-months/year |
$(-211) - $ |
$(-71) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $192,977 Cost: $453,704 |
$161,555 | 1,819,384 | $31,704 | 1,404 | $(-211) | - | $(-71) | - | $161,555 1,819,384 kWh |
$31,704 1,404 kW-months/year |
$(-211) - $ |
$(-71) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |