IAC logo
IAC Assessment: SF0597
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0597
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2023
Principal Product Energetic Aerospace Devices
NAICS 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing
SIC 3728 - Aircraft Parts And Equipment, Nec
Sales $100,000,000-$500,000,000
# of Employees 500
Plant Area (Sq.Ft.) 180,000
Annual Production 7,500 Units
Production Hrs. Annual 5,228
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $322,289 2,693,065 kWh $0.12
Electricity Demand $231,630 7,419 kW-months/year $31.22
LPG $101,295 3,428 MMBtu $29.55
TOTAL ENERGY COSTS $655,214
RECOMMENDED SAVINGS* $392,408 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $391,702
#|Description Savings
Cost
Status Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG
$ kWh $ kW-months/year $ MMBtu
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$4,268
Cost:
-
- - $4,268 59 - - -
-
kWh
$4,268
59
kW-months/year
-
-
MMBtu
02: 2.7131 ADD AREA LIGHTING SWITCHES Savings:
$11,388
Cost:
$100
$11,388 95,139 - - - - $11,388
95,139
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$53,882
Cost:
$13,192
$12,350 103,174 - - $41,532 1,405 $12,350
103,174
kWh
-
-
kW-months/year
$41,532
1,405
MMBtu
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$706
Cost:
$200
$474 3,960 $232 7 - - $474
3,960
kWh
$232
7
kW-months/year
-
-
MMBtu
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$322,164
Cost:
$2,251,041
$322,164 2,691,431 - - - - $322,164
2,691,431
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$392,408
Cost:
$2,264,533
$346,376 2,893,704 $4,500 67 $41,532 1,405 $346,376
2,893,704
kWh
$4,500
67
kW-months/year
$41,532
1,405
MMBtu
TOTAL IMPLEMENTED Savings:
$391,702
Cost:
$2,264,333
$345,902 2,889,744 $4,268 59 $41,532 1,405 $345,902
2,889,744
kWh
$4,268
59
kW-months/year
$41,532
1,405
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG