IAC logo
IAC Assessment: SF0614
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0614
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2024
Principal Product Wine
NAICS 312130 - Wineries
SIC 2084 - Wines, Brandy, And Brandy Spirits
Sales $5,000,000-$10,000,000
# of Employees 73
Plant Area (Sq.Ft.) 234,000
Annual Production 2,200,000 Units
Production Hrs. Annual 3,744
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $291,218 1,242,294 kWh $0.23
Electricity Demand $86,024 4,825 kW-months/year $17.83
Natural Gas $26,610 1,422 MMBtu $18.71
TOTAL ENERGY COSTS $403,852
RECOMMENDED SAVINGS* $560,353 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Usage Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Water Usage Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ Tgal $ $ $ $
01: 3.4151 MINIMIZE WATER USAGE Savings:
$26,559
Cost:
$990
- - - - $26,559 2,459 - - - - -
-
kWh
-
-
kW-months/year
$26,559
2,459
Tgal
-
-
$
-
-
$
02: 2.7495 INSTALL REPLACEMENT DOORS Savings:
$18,319
Cost:
$3,440
$18,319 78,165 - - - - - - - - $18,319
78,165
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
-
-
$
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$1,093
Cost:
$915
$1,093 4,662 - - - - - - - - $1,093
4,662
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$41,821
Cost:
$44,432
$32,468 138,513 $2,354 132 - - $4,548 - $2,451 - $32,468
138,513
kWh
$2,354
132
kW-months/year
-
-
Tgal
$4,548
-
$
$2,451
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$928
Cost:
$1,336
$928 3,960 - - - - - - - - $928
3,960
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
-
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$5,096
Cost:
$15,079
$5,096 21,741 - - - - - - - - $5,096
21,741
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
-
-
$
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$10,200
Cost:
$39,025
$10,200 43,516 - - - - - - - - $10,200
43,516
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
-
-
$
08: 3.4151 MINIMIZE WATER USAGE Savings:
$30,298
Cost:
$117,500
$(-2,461) (-10,500) - - $21,092 1,953 $11,667 - - - $(-2,461)
(-10,500)
kWh
-
-
kW-months/year
$21,092
1,953
Tgal
$11,667
-
$
-
-
$
09: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$13,015
Cost:
$65,531
$7,018 29,941 $321 18 $5,676 526 - - - - $7,018
29,941
kWh
$321
18
kW-months/year
$5,676
526
Tgal
-
-
$
-
-
$
10: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$297,557
Cost:
$1,115,655
$297,557 1,269,441 - - - - - - - - $297,557
1,269,441
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
-
-
$
11: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION Savings:
$115,467
Cost:
$137,973
- - - - - - - - $115,467 - -
-
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
$115,467
-
$
TOTAL RECOMMENDED Savings:
$560,353
Cost:
$1,541,876
$370,218 1,579,439 $2,675 150 $53,327 4,938 $16,215 - $117,918 - $370,218
1,579,439
kWh
$2,675
150
kW-months/year
$53,327
4,938
Tgal
$16,215
-
$
$117,918
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ Tgal $ $ $ $
Electricity Usage Electricity Demand Water Usage Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Water Usage Personnel Changes Ancillary Material Cost