Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2024 |
Principal Product | Treated wastewater |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $1,000,000-$5,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 1,600,000 |
Annual Production | 5,110,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,541,562 | 6,803,344 | kWh | $0.23 |
Electricity Demand | $535,088 | 12,010 | kW-months/year | $44.55 |
Electricity Fees | $13,544 | - | $ | - |
Natural Gas | $62,561 | 3,507 | MMBtu | $17.84 |
Other Gas | $1 | 53,340 | MMBtu | $0.00 |
TOTAL ENERGY COSTS | $2,152,756 | |||
RECOMMENDED SAVINGS* | $2,615,351 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $101,612 Cost: $3,840 |
$80,068 | 353,344 | $21,544 | 484 | - | - | - | - | - | - |
$80,068 353,344 kWh |
$21,544 484 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $39,113 Cost: $24,553 |
$15,860 | 66,991 | $7,831 | 176 | - | - | $15,880 | - | $(-458) | - |
$15,860 66,991 kWh |
$7,831 176 kW-months/year |
- - $ |
$15,880 - $ |
$(-458) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $81,460 Cost: $95,723 |
$64,192 | 283,284 | $17,268 | 388 | - | - | - | - | - | - |
$64,192 283,284 kWh |
$17,268 388 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $11,663 Cost: $52,983 |
$9,204 | 40,619 | $2,459 | 55 | - | - | - | - | - | - |
$9,204 40,619 kWh |
$2,459 55 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $83,597 Cost: $429,096 |
$60,856 | 268,562 | $34,161 | 767 | - | - | $8,409 | - | $(-19,829) | - |
$60,856 268,562 kWh |
$34,161 767 kW-months/year |
- - $ |
$8,409 - $ |
$(-19,829) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $1,786,404 Cost: $4,187,700 |
$1,541,638 | 6,803,343 | - | - | $420,507 | - | $(-175,741) | - | - | - |
$1,541,638 6,803,343 kWh |
- - kW-months/year |
$420,507 - $ |
$(-175,741) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL |
Savings: $511,502 Cost: $6,765,825 |
- | - | $511,502 | 11,482 | - | - | - | - | - | - |
- - kWh |
$511,502 11,482 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $2,615,351 Cost: $11,559,720 |
$1,771,818 | 7,816,143 | $594,765 | 13,351 | $420,507 | - | $(-151,452) | - | $(-20,287) | - | $1,771,818 7,816,143 kWh |
$594,765 13,351 kW-months/year |
$420,507 - $ |
$(-151,452) - $ |
$(-20,287) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost |