Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2024 |
Principal Product | Dairy and sauce, Olive oil package |
NAICS | 311514 - Dry, Condensed, and Evaporated Dairy Product Manufacturing |
SIC | 2023 - Dry, Condensed, Evaporated Products |
Sales | $100,000,000-$500,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 640,000 |
Annual Production | 91,000,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,056,336 | 5,396,550 | kWh | $0.20 |
Electricity Demand | $275,563 | 12,976 | kW-months/year | $21.24 |
Natural Gas | $836,273 | 58,633 | MMBtu | $14.26 |
TOTAL ENERGY COSTS | $3,091,515 | |||
RECOMMENDED SAVINGS* | $682,145 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $12,755 Cost: $300 |
$11,448 | 58,499 | $1,307 | 62 | - | - | - | - | - | - | - | - |
$11,448 58,499 kWh |
$1,307 62 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,882 Cost: - |
$6,082 | 31,080 | - | - | - | - | - | - | - | - | $(-1,200) | - |
$6,082 31,080 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$(-1,200) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $6,435 Cost: $478 |
- | - | - | - | $6,435 | 436 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,435 436 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES |
Savings: $7,560 Cost: $700 |
- | - | - | - | - | - | $2,797 | 252 | $4,763 | 252 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,797 252 Tgal |
$4,763 252 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2111 INSTALL STEAM TRAP |
Savings: $9,822 Cost: $1,988 |
- | - | - | - | $9,822 | 689 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,822 689 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $335,892 Cost: $109,275 |
- | - | - | - | $178,920 | 12,547 | $58,080 | 5,232 | $98,892 | 5,232 | - | - |
- - kWh |
- - kW-months/year |
$178,920 12,547 MMBtu |
$58,080 5,232 Tgal |
$98,892 5,232 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $6,048 Cost: $1,839 |
- | - | - | - | - | - | $2,238 | 202 | $3,810 | 202 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,238 202 Tgal |
$3,810 202 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $6,248 Cost: $2,796 |
$6,248 | 31,924 | - | - | - | - | - | - | - | - | - | - |
$6,248 31,924 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $17,564 Cost: $9,294 |
- | - | - | - | $17,564 | 1,232 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$17,564 1,232 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4145 INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE |
Savings: $26,726 Cost: $23,394 |
$23,132 | 118,199 | $3,594 | 169 | - | - | - | - | - | - | - | - |
$23,132 118,199 kWh |
$3,594 169 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER |
Savings: $9,426 Cost: $15,810 |
- | - | - | - | $9,426 | 661 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,426 661 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $238,787 Cost: $1,065,639 |
$238,787 | 1,220,268 | - | - | - | - | - | - | - | - | - | - |
$238,787 1,220,268 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $682,145 Cost: $1,231,513 |
$285,697 | 1,459,970 | $4,901 | 231 | $222,167 | 15,565 | $63,115 | 5,686 | $107,465 | 5,686 | $(-1,200) | - | $285,697 1,459,970 kWh |
$4,901 231 kW-months/year |
$222,167 15,565 MMBtu |
$63,115 5,686 Tgal |
$107,465 5,686 Tgal |
$(-1,200) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||