Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2025 |
Principal Product | Tempered Glass |
NAICS | 327211 - Flat Glass Manufacturing |
SIC | 3211 - Flat Glass |
Sales | $10,000,000-$50,000,000 |
# of Employees | 85 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 13,200,000 Units |
Production Hrs. Annual | 6,240 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,189,189 | 7,881,360 | kWh | $0.15 |
Electricity Demand | $1,452,723 | 25,898 | kW-months/year | $56.09 |
Natural Gas | $1,097 | 45 | MMBtu | $24.54 |
TOTAL ENERGY COSTS | $2,643,009 | |||
RECOMMENDED SAVINGS* | $128,627 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,190 Cost: - |
$7,150 | 47,380 | - | - | - | - | $(-960) | - | - | - |
$7,150 47,380 kWh |
- - kW-months/year |
- - $ |
$(-960) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $11,091 Cost: - |
$6,467 | 42,855 | $4,624 | 82 | - | - | - | - | - | - |
$6,467 42,855 kWh |
$4,624 82 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $25,314 Cost: $6,300 |
$25,314 | 167,753 | - | - | - | - | - | - | - | - |
$25,314 167,753 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $55,964 Cost: $17,866 |
$55,964 | 370,871 | - | - | - | - | - | - | - | - |
$55,964 370,871 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $3,706 Cost: $2,070 |
- | - | - | - | $3,706 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,706 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $9,362 Cost: $8,453 |
$5,458 | 36,172 | $3,904 | 70 | - | - | - | - | - | - |
$5,458 36,172 kWh |
$3,904 70 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,856 Cost: $6,881 |
$6,856 | 45,492 | - | - | - | - | - | - | - | - |
$6,856 45,492 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2447 HEAT WATER WITH EXHAUST HEAT |
Savings: $9,559 Cost: $18,756 |
$5,588 | 37,032 | $3,971 | 71 | - | - | - | - | - | - |
$5,588 37,032 kWh |
$3,971 71 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $585 Cost: $1,248 |
$509 | 3,374 | - | - | - | - | $24 | - | $52 | - |
$509 3,374 kWh |
- - kW-months/year |
- - $ |
$24 - $ |
$52 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $128,627 Cost: $61,574 |
$113,306 | 750,929 | $12,499 | 223 | $3,706 | - | $(-936) | - | $52 | - | $113,306 750,929 kWh |
$12,499 223 kW-months/year |
$3,706 - $ |
$(-936) - $ |
$52 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material |