IAC logo
IAC Assessment: SJ0015
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SJ0015
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Jose State University
Assessment Year 2024
Principal Product Aircraft interior parts
NAICS 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing
SIC 3728 - Aircraft Parts And Equipment, Nec
Sales $100,000,000-$500,000,000
# of Employees 559
Plant Area (Sq.Ft.) 135,000
Annual Production 100,000 Units
Production Hrs. Annual 4,160
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $311,676 2,623,622 kWh $0.12
Electricity Demand $477,997 11,579 kW-months/year $41.28
Natural Gas $83,255 4,756 MMBtu $17.51
TOTAL ENERGY COSTS $872,928
RECOMMENDED SAVINGS* $344,234 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$179,675
Cost:
$962,431
$149,608 1,259,328 $30,067 728 - - $149,608
1,259,328
kWh
$30,067
728
kW-months/year
-
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,301
Cost:
$7,684
$3,597 30,278 $2,704 66 - - $3,597
30,278
kWh
$2,704
66
kW-months/year
-
-
$
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$676
Cost:
$680
$676 5,691 - - - - $676
5,691
kWh
-
-
kW-months/year
-
-
$
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$3,809
Cost:
$766
$3,173 26,713 $636 15 - - $3,173
26,713
kWh
$636
15
kW-months/year
-
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,211
Cost:
$98
$1,211 10,196 - - - - $1,211
10,196
kWh
-
-
kW-months/year
-
-
$
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,763
Cost:
-
$1,546 13,014 $217 5 - - $1,546
13,014
kWh
$217
5
kW-months/year
-
-
$
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,620
Cost:
$1,986
$2,233 18,795 $387 9 - - $2,233
18,795
kWh
$387
9
kW-months/year
-
-
$
08: 2.8112 COMBINE UTILITY METERS Savings:
$1,748
Cost:
-
- - - - $1,748 - -
-
kWh
-
-
kW-months/year
$1,748
-
$
09: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$146,431
Cost:
-
- - $146,431 3,552 - - -
-
kWh
$146,431
3,552
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$344,234
Cost:
$973,645
$162,044 1,364,015 $180,442 4,376 $1,748 - $162,044
1,364,015
kWh
$180,442
4,376
kW-months/year
$1,748
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost