IAC logo
IAC Assessment: SJ0037
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SJ0037
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Jose State University
Assessment Year 2025
Principal Product vegetable seeds
NAICS 115114 - Postharvest Crop Activities (except Cotton Ginning)
SIC 0723 - Crop Preparation Services For Market
Sales $100,000,000-$500,000,000
# of Employees 130
Plant Area (Sq.Ft.) 225,000
Annual Production 500,000 Units
Production Hrs. Annual 2,340
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $286,912 2,557,268 kWh $0.11
Electricity Demand $99,397 7,382 kW-months/year $13.46
Natural Gas $75,399 3,455 MMBtu $21.82
TOTAL ENERGY COSTS $461,708
RECOMMENDED SAVINGS* $51,612 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$4,094
Cost:
$6,718
$3,515 30,562 $579 43 $3,515
30,562
kWh
$579
43
kW-months/year
02: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$5,561
Cost:
$4,556
$5,561 48,355 - - $5,561
48,355
kWh
-
-
kW-months/year
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$5,297
Cost:
$4,052
$5,297 46,065 - - $5,297
46,065
kWh
-
-
kW-months/year
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,703
Cost:
$12,724
$2,939 25,553 $1,764 131 $2,939
25,553
kWh
$1,764
131
kW-months/year
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$25,500
Cost:
-
$25,500 221,765 - - $25,500
221,765
kWh
-
-
kW-months/year
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$893
Cost:
-
$893 7,763 - - $893
7,763
kWh
-
-
kW-months/year
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,182
Cost:
$12,705
$4,148 36,072 $1,034 77 $4,148
36,072
kWh
$1,034
77
kW-months/year
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$382
Cost:
$3,108
$382 3,321 - - $382
3,321
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$51,612
Cost:
$43,863
$48,235 419,456 $3,377 251 $48,235
419,456
kWh
$3,377
251
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand