IAC Center | Syracuse University |
---|---|
Assessment Year | 2003 |
Principal Product | Metal Finishing |
NAICS | 332813 - Electroplating, Plating, Polishing, Anodizing, and Coloring |
SIC | 3471 - Plating And Polishing |
Sales | $1,000,000-$5,000,000 |
# of Employees | 25 |
Plant Area (Sq.Ft.) | 32,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 2,340 |
Location (State) | NY |
View Case Study |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $39,651 | 780,000 | kWh | $0.05 |
Electricity Demand | $42,521 | 3,210 | kW-months/year | $13.25 |
Electricity Fees | $13,179 | - | $ | - |
Natural Gas | $47,036 | 9,045 | MMBtu | $5.20 |
TOTAL ENERGY COSTS | $145,887 | |||
RECOMMENDED SAVINGS* | $29,357 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $29,357 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5145 RECOVER AND REUSE SPENT ACID BATHS |
Savings: $21,400 Cost: $1,800 |
- | - | - | - | - | - | $21,400 | 6,600 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$21,400 6,600 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,081 Cost: $8,364 |
$1,541 | 22,658 | $1,540 | 116 | - | - | - | - |
$1,541 22,658 kWh |
$1,540 116 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,283 Cost: $995 |
- | - | - | - | $2,283 | 439 | - | - |
- - kWh |
- - kW-months/year |
$2,283 439 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,534 Cost: $327 |
$1,534 | 22,556 | - | - | - | - | - | - |
$1,534 22,556 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,059 Cost: - |
$542 | 7,969 | $517 | 39 | - | - | - | - |
$542 7,969 kWh |
$517 39 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,357 Cost: $11,486 |
$3,617 | 53,183 | $2,057 | 155 | $2,283 | 439 | $21,400 | 6,600 | $3,617 53,183 kWh |
$2,057 155 kW-months/year |
$2,283 439 MMBtu |
$21,400 6,600 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $29,357 Cost: $11,486 |
$3,617 | 53,183 | $2,057 | 155 | $2,283 | 439 | $21,400 | 6,600 | $3,617 53,183 kWh |
$2,057 155 kW-months/year |
$2,283 439 MMBtu |
$21,400 6,600 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) |