IAC logo
IAC Assessment: SU0159
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SU0159
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2003
Principal Product Electrical Insulating Sleeves
NAICS 325211 - Plastics Material and Resin Manufacturing
SIC 3699 - Electrical Equipment & Supplies, Nec
Sales $5,000,000-$10,000,000
# of Employees 90
Plant Area (Sq.Ft.) 140,000
Annual Production 1,000 Thousand Feet
Production Hrs. Annual 6,000
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $114,674 1,758,883 kWh $0.07
Electricity Demand $68,979 5,580 kW-months/year $12.36
Electricity Fees $13,648 - $ -
Natural Gas $17,067 5,951 MMBtu $2.87
TOTAL ENERGY COSTS $214,368
RECOMMENDED SAVINGS* $16,254 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,810
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2492 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR Savings:
$5,869
Cost:
$18,122
- - - - $5,869 2,024 -
-
kWh
-
-
kW-months/year
$5,869
2,024
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,575
Cost:
$15,750
$4,120 58,860 $1,455 118 - - $4,120
58,860
kWh
$1,455
118
kW-months/year
-
-
MMBtu
03: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$1,187
Cost:
$800
$877 12,527 $310 25 - - $877
12,527
kWh
$310
25
kW-months/year
-
-
MMBtu
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,171
Cost:
-
$865 12,360 $306 25 - - $865
12,360
kWh
$306
25
kW-months/year
-
-
MMBtu
05: 2.1224 REPLACE BOILER Savings:
$1,148
Cost:
$13,507
- - - - $1,148 396 -
-
kWh
-
-
kW-months/year
$1,148
396
MMBtu
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,028
Cost:
-
$760 10,859 $268 22 - - $760
10,859
kWh
$268
22
kW-months/year
-
-
MMBtu
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$276
Cost:
$523
$202 2,891 $74 6 - - $202
2,891
kWh
$74
6
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$16,254
Cost:
$48,702
$6,824 97,497 $2,413 196 $7,017 2,420 $6,824
97,497
kWh
$2,413
196
kW-months/year
$7,017
2,420
MMBtu
TOTAL IMPLEMENTED Savings:
$4,810
Cost:
$14,830
$2,704 38,637 $958 78 $1,148 396 $2,704
38,637
kWh
$958
78
kW-months/year
$1,148
396
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas