Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2003 |
Principal Product | transportation parts |
NAICS | 332912 - Fluid Power Valve and Hose Fitting Manufacturing |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 241,969 |
Annual Production | 350,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $235,284 | 4,842,000 | kWh | $0.05 |
Electricity Demand | $55,762 | 9,360 | kW-months/year | $5.96 |
TOTAL ENERGY COSTS | $291,046 | |||
RECOMMENDED SAVINGS* | $147,820 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $40,125 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Water Consumption | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Personnel Changes | Water Consumption | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $5,012 Cost: $232 |
$4,255 | 69,960 | $757 | 127 | - | - | - | - | - | - |
$4,255 69,960 kWh |
$757 127 kW-months/year |
- - $ |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,388 Cost: $480 |
$4,430 | 88,612 | $958 | 161 | - | - | - | - | - | - |
$4,430 88,612 kWh |
$958 161 kW-months/year |
- - $ |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $28,125 Cost: $10,016 |
- | - | - | - | $28,125 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$28,125 - $ |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $24,270 Cost: $24,797 |
$20,364 | 407,280 | $3,906 | 55 | - | - | - | - | - | - |
$20,364 407,280 kWh |
$3,906 55 kW-months/year |
- - $ |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.522 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE |
Savings: $24,000 Cost: $19,912 |
- | - | - | - | - | - | - | - | $24,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$24,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3322 USE EXISTING DAM TO GENERATE ELECTRICITY |
Savings: $49,025 Cost: $132,000 |
$39,600 | 792,000 | $9,425 | 1,584 | - | - | - | - | - | - |
$39,600 792,000 kWh |
$9,425 1,584 kW-months/year |
- - $ |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $12,000 Cost: $68,560 |
- | - | - | - | - | - | $12,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$12,000 - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $147,820 Cost: $255,997 |
$68,649 | 1,357,852 | $15,046 | 1,927 | $28,125 | - | $12,000 | - | $24,000 | - | $68,649 1,357,852 kWh |
$15,046 1,927 kW-months/year |
$28,125 - $ |
$12,000 - Tgal |
$24,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $40,125 Cost: $78,576 |
- | - | - | - | $28,125 | - | $12,000 | - | - | - | - - kWh |
- - kW-months/year |
$28,125 - $ |
$12,000 - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Water Consumption | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Personnel Changes | Water Consumption | One-time Revenue or Avoided Cost |