Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2004
Principal Product Processed Fruit
NAICS 311421 - Fruit and Vegetable Canning
SIC 2030 -
Sales $10,000,000-$50,000,000
# of Employees 152
Plant Area (Sq.Ft.) 100,000
Annual Production 80,000 Pieces
Production Hrs. Annual 6,240
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $348,884 6,408,000 kWh $0.05
Electricity Demand $167,416 18,960 kW-months/year $8.83
LPG $232,611 22,859 MMBtu $10.18
TOTAL ENERGY COSTS $748,911
RECOMMENDED SAVINGS* $133,176 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $124,014
#|Description Savings
Cost
Status Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG
$ kWh $ kW-months/year $ MMBtu
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$839
Cost:
-
$565 11,315 $274 31 - - $565
11,315
kWh
$274
31
kW-months/year
-
-
MMBtu
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$99,155
Cost:
$3,104
$72,930 1,458,600 $26,225 2,970 - - $72,930
1,458,600
kWh
$26,225
2,970
kW-months/year
-
-
MMBtu
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$3,889
Cost:
$896
- - - - $3,889 382 -
-
kWh
-
-
kW-months/year
$3,889
382
MMBtu
04: 3.4151 MINIMIZE WATER USAGE Savings:
$1,683
Cost:
$427
$350 7,000 - - $1,333 131 $350
7,000
kWh
-
-
kW-months/year
$1,333
131
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,174
Cost:
$6,679
$5,525 110,500 $2,649 300 - - $5,525
110,500
kWh
$2,649
300
kW-months/year
-
-
MMBtu
06: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT Savings:
$9,764
Cost:
$8,647
- - - - $9,764 962 -
-
kWh
-
-
kW-months/year
$9,764
962
MMBtu
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$510
Cost:
$468
$375 7,514 $135 15 - - $375
7,514
kWh
$135
15
kW-months/year
-
-
MMBtu
08: 3.6122 INSTALL SOLID WASTE INCINERATOR FOR HEAT Savings:
$9,162
Cost:
$8,765
- - - - $9,162 900 -
-
kWh
-
-
kW-months/year
$9,162
900
MMBtu
TOTAL RECOMMENDED Savings:
$133,176
Cost:
$28,986
$79,745 1,594,929 $29,283 3,316 $24,148 2,375 $79,745
1,594,929
kWh
$29,283
3,316
kW-months/year
$24,148
2,375
MMBtu
TOTAL IMPLEMENTED Savings:
$124,014
Cost:
$20,221
$79,745 1,594,929 $29,283 3,316 $14,986 1,475 $79,745
1,594,929
kWh
$29,283
3,316
kW-months/year
$14,986
1,475
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG