Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2004
Principal Product Newspapers
NAICS 511110 - Newspaper Publishers
SIC 2711 - Newspapers
Sales $50,000,000-$100,000,000
# of Employees 550
Plant Area (Sq.Ft.) 142,000
Annual Production 43,000,000 Pieces
Production Hrs. Annual 8,736
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $322,919 4,851,033 kWh $0.07
Electricity Demand $81,562 10,295 kW-months/year $7.92
Electricity Fees $87,741 - $ -
TOTAL ENERGY COSTS $492,222
RECOMMENDED SAVINGS* $63,997 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $28,661
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$11,244
Cost:
-
$9,779 134,367 $1,465 185 $9,779
134,367
kWh
$1,465
185
kW-months/year
02: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$8,932
Cost:
-
$6,857 103,107 $2,075 262 $6,857
103,107
kWh
$2,075
262
kW-months/year
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$1,560
Cost:
-
$1,006 14,947 $554 70 $1,006
14,947
kWh
$554
70
kW-months/year
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$4,821
Cost:
$264
$4,194 57,611 $627 79 $4,194
57,611
kWh
$627
79
kW-months/year
05: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$15,188
Cost:
$1,545
$10,491 144,134 $4,697 593 $10,491
144,134
kWh
$4,697
593
kW-months/year
06: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$7,821
Cost:
$1,000
$6,807 93,466 $1,014 128 $6,807
93,466
kWh
$1,014
128
kW-months/year
07: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$2,229
Cost:
$368
$1,928 27,518 $301 38 $1,928
27,518
kWh
$301
38
kW-months/year
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$12,202
Cost:
$6,469
$10,618 145,821 $1,584 200 $10,618
145,821
kWh
$1,584
200
kW-months/year
TOTAL RECOMMENDED Savings:
$63,997
Cost:
$9,646
$51,680 720,971 $12,317 1,555 $51,680
720,971
kWh
$12,317
1,555
kW-months/year
TOTAL IMPLEMENTED Savings:
$28,661
Cost:
$1,913
$22,198 306,019 $6,463 816 $22,198
306,019
kWh
$6,463
816
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand