Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2004 |
Principal Product | Newspaper Publishing |
NAICS | 511110 - Newspaper Publishers |
SIC | 2711 - Newspapers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 240 |
Plant Area (Sq.Ft.) | 62,080 |
Annual Production | 30,000,000 Pieces |
Production Hrs. Annual | 5,148 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $43,786 | 943,840 | kWh | $0.05 |
Electricity Demand | $28,927 | 1,942 | kW-months/year | $14.90 |
Natural Gas | $14,979 | 1,735 | MMBtu | $8.63 |
TOTAL ENERGY COSTS | $87,692 | |||
RECOMMENDED SAVINGS* | $11,813 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,523 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,548 Cost: - |
$743 | 16,146 | $805 | 54 | - | - | - | - | - | - |
$743 16,146 kWh |
$805 54 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $3,782 Cost: - |
- | - | - | - | - | - | - | - | $3,782 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$3,782 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $205 Cost: - |
$116 | 2,523 | $89 | 6 | - | - | - | - | - | - |
$116 2,523 kWh |
$89 6 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $891 Cost: $180 |
$504 | 10,965 | $387 | 26 | - | - | - | - | - | - |
$504 10,965 kWh |
$387 26 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $97 Cost: $108 |
$52 | 1,133 | $45 | 3 | - | - | - | - | - | - |
$52 1,133 kWh |
$45 3 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $361 Cost: $500 |
$29 | 630 | $15 | 1 | - | - | $264 | - | $53 | - |
$29 630 kWh |
$15 1 kW-months/year |
- - MMBtu |
$264 - $ |
$53 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,329 Cost: $3,430 |
$703 | 15,288 | $626 | 42 | - | - | - | - | - | - |
$703 15,288 kWh |
$626 42 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $3,600 Cost: $19,500 |
- | - | - | - | $3,600 | 417 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,600 417 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $11,813 Cost: $23,718 |
$2,147 | 46,685 | $1,967 | 132 | $3,600 | 417 | $264 | - | $3,835 | - | $2,147 46,685 kWh |
$1,967 132 kW-months/year |
$3,600 417 MMBtu |
$264 - $ |
$3,835 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,523 Cost: $288 |
$1,415 | 30,767 | $1,326 | 89 | - | - | - | - | $3,782 | - | $1,415 30,767 kWh |
$1,326 89 kW-months/year |
- - MMBtu |
- - $ |
$3,782 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |