Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2006 |
Principal Product | Wine |
NAICS | 312130 - Wineries |
SIC | 2084 - Wines, Brandy, And Brandy Spirits |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 272,500 |
Annual Production | 3,000,000 Pieces |
Production Hrs. Annual | 3,060 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $332,264 | 4,301,850 | kWh | $0.08 |
Electricity Demand | $50,380 | 13,235 | kW-months/year | $3.81 |
Electricity Fees | $7,027 | - | $ | - |
Natural Gas | $278,244 | 26,228 | MMBtu | $10.61 |
TOTAL ENERGY COSTS | $667,915 | |||
RECOMMENDED SAVINGS* | $34,828 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,879 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,070 Cost: - |
$839 | 10,487 | $231 | 77 | - | - | - | - | - | - |
$839 10,487 kWh |
$231 77 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $434 Cost: - |
$359 | 4,488 | $75 | 25 | - | - | - | - | - | - |
$359 4,488 kWh |
$75 25 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $209 Cost: - |
- | - | - | - | - | - | - | - | $209 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$209 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $13,581 Cost: $2,035 |
- | - | - | - | - | - | $13,581 | 1,280 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$13,581 1,280 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $11,968 Cost: $1,970 |
$8,585 | 136,274 | $3,383 | 366 | - | - | - | - | - | - |
$8,585 136,274 kWh |
$3,383 366 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,737 Cost: $496 |
$1,515 | 18,941 | $222 | 74 | - | - | - | - | - | - |
$1,515 18,941 kWh |
$222 74 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $629 Cost: $228 |
$548 | 6,854 | $81 | 27 | - | - | - | - | - | - |
$548 6,854 kWh |
$81 27 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1231 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS |
Savings: $2,257 Cost: $1,220 |
- | - | - | - | - | - | - | - | $2,257 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$2,257 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $725 Cost: $1,187 |
$410 | 5,500 | $34 | 7 | - | - | - | - | $281 | - |
$410 5,500 kWh |
$34 7 kW-months/year |
- - $ |
- - MMBtu |
$281 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $607 Cost: $1,187 |
$571 | 7,358 | $36 | 10 | - | - | - | - | - | - |
$571 7,358 kWh |
$36 10 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $91 Cost: $194 |
$91 | 1,139 | - | - | - | - | - | - | - | - |
$91 1,139 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,520 Cost: $13,971 |
- | - | - | - | $1,520 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,520 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,828 Cost: $22,488 |
$12,918 | 191,041 | $4,062 | 586 | $1,520 | - | $13,581 | 1,280 | $2,747 | - | $12,918 191,041 kWh |
$4,062 586 kW-months/year |
$1,520 - $ |
$13,581 1,280 MMBtu |
$2,747 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,879 Cost: $1,609 |
$1,408 | 17,981 | $190 | 59 | - | - | - | - | $281 | - | $1,408 17,981 kWh |
$190 59 kW-months/year |
- - $ |
- - MMBtu |
$281 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost |