IAC logo
IAC Assessment: SU0263
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SU0263
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2008
Principal Product Digital Cameras
NAICS 334516 - Analytical Laboratory Instrument Manufacturing
SIC 3399 - Primary Metal Products, Nec
Sales $5,000,000-$10,000,000
# of Employees 27
Plant Area (Sq.Ft.) 14,700
Annual Production 2,500 Pieces
Production Hrs. Annual 3,080
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $41,635 358,059 kWh $0.12
Electricity Demand $8,154 825 kW-months/year $9.88
TOTAL ENERGY COSTS $49,789
RECOMMENDED SAVINGS* $17,596 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,870
#|Description Savings
Cost
Status Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$4,456
Cost:
-
$4,456 38,416 - - - - $4,456
38,416
kWh
-
-
kW-months/year
-
-
$
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$3,305
Cost:
-
- - - - $3,305 - -
-
kWh
-
-
kW-months/year
$3,305
-
$
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$335
Cost:
-
$295 2,543 $40 4 - - $295
2,543
kWh
$40
4
kW-months/year
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,384
Cost:
$100
$3,028 26,105 $356 36 - - $3,028
26,105
kWh
$356
36
kW-months/year
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,354
Cost:
$121
$1,008 8,686 $346 35 - - $1,008
8,686
kWh
$346
35
kW-months/year
-
-
$
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,614
Cost:
$408
$2,337 20,148 $277 28 - - $2,337
20,148
kWh
$277
28
kW-months/year
-
-
$
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$230
Cost:
$258
$230 1,980 - - - - $230
1,980
kWh
-
-
kW-months/year
-
-
$
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$307
Cost:
$474
$307 2,649 - - - - $307
2,649
kWh
-
-
kW-months/year
-
-
$
09: 2.7314 REDUCE VENTILATION AIR Savings:
$1,611
Cost:
$13,919
$1,581 13,631 $30 3 - - $1,581
13,631
kWh
$30
3
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$17,596
Cost:
$15,280
$13,242 114,158 $1,049 106 $3,305 - $13,242
114,158
kWh
$1,049
106
kW-months/year
$3,305
-
$
TOTAL IMPLEMENTED Savings:
$6,870
Cost:
$1,240
$6,197 53,425 $673 68 - - $6,197
53,425
kWh
$673
68
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost