Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2008 |
Principal Product | Wooden Shipping Boxes |
NAICS | 322211 - Corrugated and Solid Fiber Box Manufacturing |
SIC | 2449 - Wood Containers, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 119 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 2,300,000 Pieces |
Production Hrs. Annual | 4,394 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $74,279 | 691,654 | kWh | $0.11 |
Electricity Demand | $43,011 | 2,478 | kW-months/year | $17.36 |
Electricity Fees | $3,786 | - | $ | - |
Natural Gas | $39,351 | 3,647 | MMBtu | $10.79 |
TOTAL ENERGY COSTS | $315,427 | |||
RECOMMENDED SAVINGS* | $174,468 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $173,184 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $2,198 Cost: - |
$2,198 | 20,544 | - | - | - | - | - | - |
$2,198 20,544 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $913 Cost: - |
$635 | 5,932 | $278 | 16 | - | - | - | - |
$635 5,932 kWh |
$278 16 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $527 Cost: - |
$371 | 3,471 | $156 | 9 | - | - | - | - |
$371 3,471 kWh |
$156 9 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,164 Cost: $198 |
$1,505 | 14,061 | $659 | 38 | - | - | - | - |
$1,505 14,061 kWh |
$659 38 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,485 Cost: $209 |
$1,034 | 9,667 | $451 | 26 | - | - | - | - |
$1,034 9,667 kWh |
$451 26 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,570 Cost: $333 |
$1,097 | 10,249 | $243 | 14 | $142 | - | $88 | - |
$1,097 10,249 kWh |
$243 14 kW-months/year |
$142 - $ |
$88 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,786 Cost: $2,539 |
$2,624 | 24,519 | $1,162 | 67 | - | - | - | - |
$2,624 24,519 kWh |
$1,162 67 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.1182 MAKE A NEW BY-PRODUCT |
Savings: $161,000 Cost: $171,101 |
- | - | - | - | - | - | $161,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$161,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $220 Cost: $268 |
$220 | 2,059 | - | - | - | - | - | - |
$220 2,059 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $454 Cost: $718 |
$315 | 2,944 | $139 | 9 | - | - | - | - |
$315 2,944 kWh |
$139 9 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $151 Cost: $366 |
$151 | 1,407 | - | - | - | - | - | - |
$151 1,407 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $174,468 Cost: $175,732 |
$10,150 | 94,853 | $3,088 | 179 | $142 | - | $161,088 | - | $10,150 94,853 kWh |
$3,088 179 kW-months/year |
$142 - $ |
$161,088 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $173,184 Cost: $175,098 |
$9,144 | 85,455 | $2,810 | 163 | $142 | - | $161,088 | - | $9,144 85,455 kWh |
$2,810 163 kW-months/year |
$142 - $ |
$161,088 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost |