Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2012 |
Principal Product | Video Borescopes |
NAICS | 334519 - Other Measuring and Controlling Device Manufacturing |
SIC | 3599 - Industrial Machinery, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 73,900 |
Annual Production | 50,000 Pieces |
Production Hrs. Annual | 2,210 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $60,047 | 1,084,500 | kWh | $0.06 |
Electricity Demand | $9,262 | 3,497 | kW-months/year | $2.65 |
Electricity Fees | $8,178 | - | $ | - |
Natural Gas | $16,673 | 1,951 | MMBtu | $8.55 |
TOTAL ENERGY COSTS | $94,160 | |||
RECOMMENDED SAVINGS* | $23,778 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,198 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $6,386 Cost: - |
$6,386 | 106,438 | - | - | - | - | - | - | - | - |
$6,386 106,438 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7314 REDUCE VENTILATION AIR |
Savings: $12,242 Cost: $7,179 |
$623 | 10,387 | $148 | 56 | $11,471 | 1,130 | - | - | - | - |
$623 10,387 kWh |
$148 56 kW-months/year |
$11,471 1,130 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $876 Cost: $528 |
$436 | 7,271 | $26 | 10 | - | - | $150 | - | $264 | - |
$436 7,271 kWh |
$26 10 kW-months/year |
- - MMBtu |
$150 - $ |
$264 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $109 Cost: $298 |
$109 | 1,809 | - | - | - | - | - | - | - | - |
$109 1,809 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $229 Cost: $639 |
$229 | 3,805 | - | - | - | - | - | - | - | - |
$229 3,805 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7122 DISCONNECT BALLASTS |
Savings: $2,772 Cost: $9,240 |
$1,656 | 27,605 | $276 | 105 | - | - | $480 | - | $360 | - |
$1,656 27,605 kWh |
$276 105 kW-months/year |
- - MMBtu |
$480 - $ |
$360 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $1,164 Cost: $5,472 |
$1,098 | 18,308 | $66 | 25 | - | - | - | - | - | - |
$1,098 18,308 kWh |
$66 25 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $23,778 Cost: $23,356 |
$10,537 | 175,623 | $516 | 197 | $11,471 | 1,130 | $630 | - | $624 | - | $10,537 175,623 kWh |
$516 197 kW-months/year |
$11,471 1,130 MMBtu |
$630 - $ |
$624 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,198 Cost: $15,240 |
$9,576 | 159,622 | $368 | 140 | - | - | $630 | - | $624 | - | $9,576 159,622 kWh |
$368 140 kW-months/year |
- - MMBtu |
$630 - $ |
$624 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |