Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2012 |
Principal Product | Point of Sale Equipment |
NAICS | 334118 - Computer Terminal and Other Computer Peripheral Equipment Manufacturing |
SIC | 3578 - Calculating And Accounting Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 30,000 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $22,804 | 439,086 | kWh | $0.05 |
Electricity Demand | $12,472 | 1,548 | kW-months/year | $8.06 |
Natural Gas | $18,157 | 1,757 | MMBtu | $10.33 |
TOTAL ENERGY COSTS | $72,683 | |||
RECOMMENDED SAVINGS* | $19,995 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,288 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $3,908 Cost: - |
- | - | - | - | - | - | - | - | $3,908 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$3,908 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $1,326 Cost: - |
$1,326 | 25,545 | - | - | - | - | - | - | - | - |
$1,326 25,545 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $952 Cost: - |
- | - | - | - | - | - | - | - | $952 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$952 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $820 Cost: $280 |
$273 | 5,256 | $58 | 7 | - | - | $348 | - | $141 | - |
$273 5,256 kWh |
$58 7 kW-months/year |
- - MMBtu |
$348 - $ |
$141 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $4,357 Cost: $5,371 |
$(-449) | (-8,650) | $(-96) | (-12) | $4,902 | 474 | - | - | - | - |
$(-449) (-8,650) kWh |
$(-96) (-12) kW-months/year |
$4,902 474 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $426 Cost: $777 |
$426 | 8,214 | - | - | - | - | - | - | - | - |
$426 8,214 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $2,282 Cost: $6,008 |
$(-33) | (-636) | - | - | $2,315 | 224 | - | - | - | - |
$(-33) (-636) kWh |
- - kW-months/year |
$2,315 224 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.3133 USE OTHER WASTE CONCENTRATION METHODS |
Savings: $5,924 Cost: $18,000 |
$(-23) | (-434) | $(-419) | (-52) | - | - | - | - | $6,366 | - |
$(-23) (-434) kWh |
$(-419) (-52) kW-months/year |
- - MMBtu |
- - $ |
$6,366 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,995 Cost: $30,436 |
$1,520 | 29,295 | $(-457) | (-57) | $7,217 | 698 | $348 | - | $11,367 | - | $1,520 29,295 kWh |
$(-457) (-57) kW-months/year |
$7,217 698 MMBtu |
$348 - $ |
$11,367 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,288 Cost: $6,288 |
$1,566 | 30,165 | $58 | 7 | $2,315 | 224 | $348 | - | $5,001 | - | $1,566 30,165 kWh |
$58 7 kW-months/year |
$2,315 224 MMBtu |
$348 - $ |
$5,001 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||