Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2014 |
Principal Product | Gravure Printed Labels |
NAICS | 323111 - Commercial Printing (except Screen and Books) |
SIC | 2754 - Commercial Printing, Gravure |
Sales | $10,000,000-$50,000,000 |
# of Employees | 43 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 20,824,384 Units |
Production Hrs. Annual | 8,400 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $114,583 | 3,805,585 | kWh | $0.03 |
Electricity Demand | $17,402 | 5,524 | kW-months/year | $3.15 |
Electricity Fees | $6,391 | - | $ | - |
Natural Gas | $164,950 | 28,006 | MMBtu | $5.89 |
TOTAL ENERGY COSTS | $305,835 | |||
RECOMMENDED SAVINGS* | $6,782 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,902 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $509 Cost: - |
$509 | 16,954 | - | - | - | - |
$509 16,954 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,140 Cost: $521 |
$1,140 | 38,010 | - | - | - | - |
$1,140 38,010 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7122 DISCONNECT BALLASTS |
Savings: $96 Cost: - |
$96 | 3,192 | - | - | - | - |
$96 3,192 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,080 Cost: $749 |
$1,080 | 36,010 | - | - | - | - |
$1,080 36,010 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,211 Cost: $1,388 |
$2,211 | 73,712 | - | - | - | - |
$2,211 73,712 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $595 Cost: $532 |
$102 | 3,421 | $15 | 5 | $478 | - |
$102 3,421 kWh |
$15 5 kW-months/year |
$478 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $1,151 Cost: $1,668 |
- | - | - | - | $1,151 | - |
- - kWh |
- - kW-months/year |
$1,151 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $6,782 Cost: $4,858 |
$5,138 | 171,299 | $15 | 5 | $1,629 | - | $5,138 171,299 kWh |
$15 5 kW-months/year |
$1,629 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,902 Cost: $1,920 |
$2,409 | 80,325 | $15 | 5 | $478 | - | $2,409 80,325 kWh |
$15 5 kW-months/year |
$478 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes |