Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2014 |
Principal Product | Electrical Fittings |
NAICS | 335932 - Noncurrent-Carrying Wiring Device Manufacturing |
SIC | 3644 - Noncurrent-carrying Wiring Devices |
Sales | $100,000,000-$500,000,000 |
# of Employees | 505 |
Plant Area (Sq.Ft.) | 1,200,000 |
Annual Production | 3,240,000 Pieces |
Production Hrs. Annual | 7,200 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $534,736 | 9,040,073 | kWh | $0.06 |
Electricity Demand | $99,266 | 35,828 | kW-months/year | $2.77 |
Electricity Fees | $4,677 | - | $ | - |
Natural Gas | $398,038 | 67,082 | MMBtu | $5.93 |
TOTAL ENERGY COSTS | $1,059,277 | |||
RECOMMENDED SAVINGS* | $34,153 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $25,274 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,135 Cost: - |
$2,135 | 36,180 | - | - | - | - | - | - | - | - |
$2,135 36,180 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $376 Cost: - |
$337 | 5,712 | $39 | 14 | - | - | - | - | - | - |
$337 5,712 kWh |
$39 14 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $10,756 Cost: $1,527 |
$10,756 | 182,310 | - | - | - | - | - | - | - | - |
$10,756 182,310 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $3,508 Cost: $849 |
- | - | - | - | $3,508 | 592 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,508 592 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $1,288 Cost: $2,716 |
$1,288 | 21,830 | - | - | - | - | - | - | - | - |
$1,288 21,830 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $512 Cost: $1,800 |
$482 | 8,170 | $30 | 11 | - | - | - | - | - | - |
$482 8,170 kWh |
$30 11 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $8,503 Cost: $41,760 |
$(-266) | (-4,510) | $(-2,893) | (-1,044) | - | - | $2,140 | - | $9,522 | - |
$(-266) (-4,510) kWh |
$(-2,893) (-1,044) kW-months/year |
- - MMBtu |
$2,140 - $ |
$9,522 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,075 Cost: $35,370 |
$4,835 | 81,950 | $499 | 180 | - | - | $348 | - | $1,393 | - |
$4,835 81,950 kWh |
$499 180 kW-months/year |
- - MMBtu |
$348 - $ |
$1,393 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,153 Cost: $84,022 |
$19,567 | 331,642 | $(-2,325) | (-839) | $3,508 | 592 | $2,488 | - | $10,915 | - | $19,567 331,642 kWh |
$(-2,325) (-839) kW-months/year |
$3,508 592 MMBtu |
$2,488 - $ |
$10,915 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $25,274 Cost: $42,262 |
$19,496 | 330,440 | $529 | 191 | $3,508 | 592 | $348 | - | $1,393 | - | $19,496 330,440 kWh |
$529 191 kW-months/year |
$3,508 592 MMBtu |
$348 - $ |
$1,393 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |