Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2014
Principal Product Fuel Cells
NAICS 334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use
SIC 3629 - Electrical Industrial Apparatus, Nec
Sales $50,000,000-$100,000,000
# of Employees 145
Plant Area (Sq.Ft.) 108,500
Annual Production 918 Pieces
Production Hrs. Annual 4,420
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $165,694 2,274,166 kWh $0.07
Electricity Demand $55,879 5,541 kW-months/year $10.08
Electricity Fees $23,243 - $ -
Natural Gas $82,232 9,761 MMBtu $8.42
TOTAL ENERGY COSTS $328,726
RECOMMENDED SAVINGS* $33,681 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $27,609
#|Description Savings
Cost
Status Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$2,567
Cost:
-
$1,478 20,250 $1,089 108 - - $1,478
20,250
kWh
$1,089
108
kW-months/year
-
-
$
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$13,052
Cost:
-
- - - - $13,052 - -
-
kWh
-
-
kW-months/year
$13,052
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$296
Cost:
-
$296 4,056 - - - - $296
4,056
kWh
-
-
kW-months/year
-
-
$
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$695
Cost:
$870
$695 9,524 - - - - $695
9,524
kWh
-
-
kW-months/year
-
-
$
05: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$533
Cost:
$704
$533 7,300 - - - - $533
7,300
kWh
-
-
kW-months/year
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$13,728
Cost:
$27,708
$9,165 125,554 $3,750 372 $813 - $9,165
125,554
kWh
$3,750
372
kW-months/year
$813
-
$
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$122
Cost:
$364
$122 1,665 - - - - $122
1,665
kWh
-
-
kW-months/year
-
-
$
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$296
Cost:
$1,020
$296 4,056 - - - - $296
4,056
kWh
-
-
kW-months/year
-
-
$
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$175
Cost:
$620
$175 2,393 - - - - $175
2,393
kWh
-
-
kW-months/year
-
-
$
10: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$2,217
Cost:
$8,640
$(-168) (-2,304) $(-2,177) (-216) $4,562 - $(-168)
(-2,304)
kWh
$(-2,177)
(-216)
kW-months/year
$4,562
-
$
TOTAL RECOMMENDED Savings:
$33,681
Cost:
$39,926
$12,592 172,494 $2,662 264 $18,427 - $12,592
172,494
kWh
$2,662
264
kW-months/year
$18,427
-
$
TOTAL IMPLEMENTED Savings:
$27,609
Cost:
$29,432
$9,994 136,910 $3,750 372 $13,865 - $9,994
136,910
kWh
$3,750
372
kW-months/year
$13,865
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost