Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2014 |
Principal Product | Fuel Cells |
NAICS | 334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use |
SIC | 3629 - Electrical Industrial Apparatus, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 145 |
Plant Area (Sq.Ft.) | 108,500 |
Annual Production | 918 Pieces |
Production Hrs. Annual | 4,420 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $165,694 | 2,274,166 | kWh | $0.07 |
Electricity Demand | $55,879 | 5,541 | kW-months/year | $10.08 |
Electricity Fees | $23,243 | - | $ | - |
Natural Gas | $82,232 | 9,761 | MMBtu | $8.42 |
TOTAL ENERGY COSTS | $328,726 | |||
RECOMMENDED SAVINGS* | $33,681 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,609 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $2,567 Cost: - |
$1,478 | 20,250 | $1,089 | 108 | - | - |
$1,478 20,250 kWh |
$1,089 108 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $13,052 Cost: - |
- | - | - | - | $13,052 | - |
- - kWh |
- - kW-months/year |
$13,052 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $296 Cost: - |
$296 | 4,056 | - | - | - | - |
$296 4,056 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $695 Cost: $870 |
$695 | 9,524 | - | - | - | - |
$695 9,524 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $533 Cost: $704 |
$533 | 7,300 | - | - | - | - |
$533 7,300 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,728 Cost: $27,708 |
$9,165 | 125,554 | $3,750 | 372 | $813 | - |
$9,165 125,554 kWh |
$3,750 372 kW-months/year |
$813 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $122 Cost: $364 |
$122 | 1,665 | - | - | - | - |
$122 1,665 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $296 Cost: $1,020 |
$296 | 4,056 | - | - | - | - |
$296 4,056 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $175 Cost: $620 |
$175 | 2,393 | - | - | - | - |
$175 2,393 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $2,217 Cost: $8,640 |
$(-168) | (-2,304) | $(-2,177) | (-216) | $4,562 | - |
$(-168) (-2,304) kWh |
$(-2,177) (-216) kW-months/year |
$4,562 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,681 Cost: $39,926 |
$12,592 | 172,494 | $2,662 | 264 | $18,427 | - | $12,592 172,494 kWh |
$2,662 264 kW-months/year |
$18,427 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,609 Cost: $29,432 |
$9,994 | 136,910 | $3,750 | 372 | $13,865 | - | $9,994 136,910 kWh |
$3,750 372 kW-months/year |
$13,865 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost |