IAC logo
IAC Assessment: SU0371
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SU0371
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2014
Principal Product Portable pneumatic power tools
NAICS 333991 - Power-Driven Handtool Manufacturing
SIC 3546 - Power-driven Handtools
Sales $50,000,000-$100,000,000
# of Employees 175
Plant Area (Sq.Ft.) 150,000
Annual Production 155,000 Pieces
Production Hrs. Annual 2,080
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $72,891 1,227,900 kWh $0.06
Electricity Demand $54,643 4,976 kW-months/year $10.98
Electricity Fees $7,365 - $ -
Natural Gas $36,235 4,605 MMBtu $7.87
TOTAL ENERGY COSTS $173,813
RECOMMENDED SAVINGS* $40,088 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $25,520
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$5,498
Cost:
-
- - - - - - $5,498 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$5,498
-
$
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$3,063
Cost:
-
$1,416 24,000 $1,647 150 - - - - $1,416
24,000
kWh
$1,647
150
kW-months/year
-
-
MMBtu
-
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,600
Cost:
-
$1,600 27,115 - - - - - - $1,600
27,115
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$405
Cost:
-
$323 5,475 $82 8 - - - - $323
5,475
kWh
$82
8
kW-months/year
-
-
MMBtu
-
-
$
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,925
Cost:
$846
$1,410 23,903 $1,515 138 - - - - $1,410
23,903
kWh
$1,515
138
kW-months/year
-
-
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,627
Cost:
$979
$396 6,710 $101 9 - - $1,130 - $396
6,710
kWh
$101
9
kW-months/year
-
-
MMBtu
$1,130
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$496
Cost:
$335
$496 8,400 - - - - - - $496
8,400
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$14,974
Cost:
$15,880
$6,167 104,526 $7,137 650 - - $1,670 - $6,167
104,526
kWh
$7,137
650
kW-months/year
-
-
MMBtu
$1,670
-
$
09: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$7,618
Cost:
$15,784
- - - - $7,618 968 - - -
-
kWh
-
-
kW-months/year
$7,618
968
MMBtu
-
-
$
10: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$179
Cost:
$562
$179 3,031 - - - - - - $179
3,031
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
11: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$1,703
Cost:
$5,670
$(-1,115) (-18,900) $(-1,976) (-180) - - $4,794 - $(-1,115)
(-18,900)
kWh
$(-1,976)
(-180)
kW-months/year
-
-
MMBtu
$4,794
-
$
TOTAL RECOMMENDED Savings:
$40,088
Cost:
$40,056
$10,872 184,260 $8,506 775 $7,618 968 $13,092 - $10,872
184,260
kWh
$8,506
775
kW-months/year
$7,618
968
MMBtu
$13,092
-
$
TOTAL IMPLEMENTED Savings:
$25,520
Cost:
$18,040
$8,469 143,539 $8,753 797 - - $8,298 - $8,469
143,539
kWh
$8,753
797
kW-months/year
-
-
MMBtu
$8,298
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost