Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2015 |
Principal Product | Point of Sale Systems |
NAICS | 333318 - Other Commercial and Service Industry Machinery Manufacturing |
SIC | 3578 - Calculating And Accounting Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 245,000 |
Annual Production | 20,000 Pieces |
Production Hrs. Annual | 2,860 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $196,206 | 2,528,269 | kWh | $0.08 |
Electricity Demand | $82,503 | 8,548 | kW-months/year | $9.65 |
Electricity Fees | $55,732 | - | $ | - |
Natural Gas | $5,871 | 993 | MMBtu | $5.91 |
TOTAL ENERGY COSTS | $340,312 | |||
RECOMMENDED SAVINGS* | $29,764 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,142 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $2,133 Cost: - |
$1,264 | 16,200 | $869 | 90 | - | - | - | - |
$1,264 16,200 kWh |
$869 90 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7122 DISCONNECT BALLASTS |
Savings: $2,373 Cost: - |
$1,562 | 20,020 | $811 | 84 | - | - | - | - |
$1,562 20,020 kWh |
$811 84 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,717 Cost: - |
$1,138 | 14,588 | $579 | 60 | - | - | - | - |
$1,138 14,588 kWh |
$579 60 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $452 Cost: $211 |
$75 | 963 | $13 | 1 | $250 | - | $114 | - |
$75 963 kWh |
$13 1 kW-months/year |
$250 - $ |
$114 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $4,789 Cost: $5,450 |
$(-753) | (-9,660) | $(-347) | (-36) | $2,025 | - | $3,864 | - |
$(-753) (-9,660) kWh |
$(-347) (-36) kW-months/year |
$2,025 - $ |
$3,864 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $446 Cost: $958 |
$381 | 4,888 | $65 | 7 | - | - | - | - |
$381 4,888 kWh |
$65 7 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $460 Cost: $950 |
$460 | 5,903 | - | - | - | - | - | - |
$460 5,903 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $17,394 Cost: $50,904 |
$14,036 | 179,945 | $3,358 | 348 | - | - | - | - |
$14,036 179,945 kWh |
$3,358 348 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,764 Cost: $58,473 |
$18,163 | 232,847 | $5,348 | 554 | $2,275 | - | $3,978 | - | $18,163 232,847 kWh |
$5,348 554 kW-months/year |
$2,275 - $ |
$3,978 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,142 Cost: $52,073 |
$16,894 | 216,584 | $4,884 | 506 | $250 | - | $114 | - | $16,894 216,584 kWh |
$4,884 506 kW-months/year |
$250 - $ |
$114 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost |