Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2015 |
Principal Product | Commercial Contract Furniture |
NAICS | 337211 - Wood Office Furniture Manufacturing |
SIC | 2521 - Wood Office Furniture |
Sales | $100,000,000-$500,000,000 |
# of Employees | 690 |
Plant Area (Sq.Ft.) | 716,484 |
Annual Production | 262,313 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $665,021 | 13,062,135 | kWh | $0.05 |
Electricity Demand | $176,722 | 38,464 | kW-months/year | $4.59 |
Electricity Fees | $10,485 | - | $ | - |
Natural Gas | $326,491 | 53,267 | MMBtu | $6.13 |
TOTAL ENERGY COSTS | $1,261,586 | |||
RECOMMENDED SAVINGS* | $83,550 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,252 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.7312 IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS |
Savings: $9,598 Cost: $5,243 |
$9,598 | 188,193 | - | - | - | - | - | - | - | - |
$9,598 188,193 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $716 Cost: $367 |
$716 | 14,040 | - | - | - | - | - | - | - | - |
$716 14,040 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,180 Cost: $2,800 |
$3,180 | 62,361 | - | - | - | - | - | - | - | - |
$3,180 62,361 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $64,843 Cost: $97,500 |
- | - | - | - | $64,843 | 10,578 | - | - | - | - |
- - kWh |
- - kW-months/year |
$64,843 10,578 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,806 Cost: $2,683 |
$1,806 | 35,414 | - | - | - | - | - | - | - | - |
$1,806 35,414 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $938 Cost: $1,414 |
- | - | - | - | $938 | 153 | - | - | - | - |
- - kWh |
- - kW-months/year |
$938 153 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $584 Cost: $2,876 |
$584 | 11,572 | - | - | - | - | - | - | - | - |
$584 11,572 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,885 Cost: $9,310 |
$1,005 | 19,710 | $248 | 54 | - | - | $912 | - | $(-280) | - |
$1,005 19,710 kWh |
$248 54 kW-months/year |
- - MMBtu |
$912 - $ |
$(-280) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $83,550 Cost: $122,193 |
$16,889 | 331,290 | $248 | 54 | $65,781 | 10,731 | $912 | - | $(-280) | - | $16,889 331,290 kWh |
$248 54 kW-months/year |
$65,781 10,731 MMBtu |
$912 - $ |
$(-280) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,252 Cost: $7,024 |
$10,314 | 202,233 | - | - | $938 | 153 | - | - | - | - | $10,314 202,233 kWh |
- - kW-months/year |
$938 153 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |