Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2015 |
Principal Product | Industrial Filtration Products |
NAICS | 333999 - All Other Miscellaneous General Purpose Machinery Manufacturing |
SIC | 3564 - Blowers And Fans |
Sales | $10,000,000-$50,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 74,000 |
Annual Production | 470,000 Pieces |
Production Hrs. Annual | 4,550 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $68,192 | 967,240 | kWh | $0.07 |
Electricity Demand | $28,121 | 3,183 | kW-months/year | $8.83 |
Electricity Fees | $423 | - | $ | - |
Natural Gas | $26,394 | 3,154 | MMBtu | $8.37 |
TOTAL ENERGY COSTS | $123,130 | |||
RECOMMENDED SAVINGS* | $33,058 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,318 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $6,287 Cost: - |
- | - | - | - | - | - | - | - | $6,287 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$6,287 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $4,921 Cost: - |
- | - | - | - | - | - | - | - | $4,921 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$4,921 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $325 Cost: - |
$192 | 2,700 | $133 | 15 | - | - | - | - | - | - |
$192 2,700 kWh |
$133 15 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $36 Cost: - |
$15 | 218 | $21 | 2 | - | - | - | - | - | - |
$15 218 kWh |
$21 2 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $5,979 Cost: $2,144 |
$3,822 | 53,836 | $3,689 | 418 | $(-1,532) | (-183) | - | - | - | - |
$3,822 53,836 kWh |
$3,689 418 kW-months/year |
$(-1,532) (-183) MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7312 IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS |
Savings: $1,555 Cost: $1,247 |
$1,555 | 21,903 | - | - | - | - | - | - | - | - |
$1,555 21,903 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7314 REDUCE VENTILATION AIR |
Savings: $2,479 Cost: $2,294 |
$520 | 7,335 | - | - | $1,959 | 234 | - | - | - | - |
$520 7,335 kWh |
- - kW-months/year |
$1,959 234 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $5,273 Cost: $6,721 |
- | - | - | - | $5,273 | 630 | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,273 630 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $517 Cost: $709 |
$517 | 7,280 | - | - | - | - | - | - | - | - |
$517 7,280 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $3,639 Cost: $5,931 |
$(-517) | (-7,276) | $(-88) | (-10) | $4,244 | 507 | - | - | - | - |
$(-517) (-7,276) kWh |
$(-88) (-10) kW-months/year |
$4,244 507 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $443 Cost: $865 |
$236 | 3,329 | $40 | 5 | - | - | $106 | - | $61 | - |
$236 3,329 kWh |
$40 5 kW-months/year |
- - MMBtu |
$106 - $ |
$61 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $1,381 Cost: $3,649 |
$(-107) | (-1,500) | $(-318) | (-36) | - | - | $882 | - | $924 | - |
$(-107) (-1,500) kWh |
$(-318) (-36) kW-months/year |
- - MMBtu |
$882 - $ |
$924 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $176 Cost: $460 |
$176 | 2,481 | - | - | - | - | - | - | - | - |
$176 2,481 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $47 Cost: $163 |
$36 | 501 | $11 | 1 | - | - | - | - | - | - |
$36 501 kWh |
$11 1 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,058 Cost: $24,183 |
$6,445 | 90,807 | $3,488 | 395 | $9,944 | 1,188 | $988 | - | $12,193 | - | $6,445 90,807 kWh |
$3,488 395 kW-months/year |
$9,944 1,188 MMBtu |
$988 - $ |
$12,193 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,318 Cost: $14,927 |
$1,517 | 21,375 | $117 | 13 | $9,517 | 1,137 | $106 | - | $61 | - | $1,517 21,375 kWh |
$117 13 kW-months/year |
$9,517 1,137 MMBtu |
$106 - $ |
$61 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |