IAC logo
IAC Assessment: SU0427
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SU0427
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2016
Principal Product Pool Liners
NAICS 326199 - All Other Plastics Product Manufacturing
SIC 3089 - Plastics Products, Nec
Sales $50,000,000-$100,000,000
# of Employees 140
Plant Area (Sq.Ft.) 120,000
Annual Production 22,000 Units
Production Hrs. Annual 4,250
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $68,522 1,070,632 kWh $0.06
Electricity Demand $37,315 3,617 kW-months/year $10.32
Electricity Fees $3,643 - $ -
Natural Gas $24,208 4,811 MMBtu $5.03
TOTAL ENERGY COSTS $193,688
RECOMMENDED SAVINGS* $13,893 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $13,458
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$442
Cost:
$317
$442 6,904 - - - - - - $442
6,904
kWh
-
-
kW-months/year
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$195
Cost:
$173
$118 1,839 $26 3 $28 - $23 - $118
1,839
kWh
$26
3
kW-months/year
$28
-
$
$23
-
$
03: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$240
Cost:
$484
$240 3,755 - - - - - - $240
3,755
kWh
-
-
kW-months/year
-
-
$
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$12,703
Cost:
$34,086
$7,790 121,720 $3,546 344 $488 - $879 - $7,790
121,720
kWh
$3,546
344
kW-months/year
$488
-
$
$879
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$124
Cost:
$556
$124 1,936 - - - - - - $124
1,936
kWh
-
-
kW-months/year
-
-
$
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$189
Cost:
$924
$189 2,949 - - - - - - $189
2,949
kWh
-
-
kW-months/year
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$13,893
Cost:
$36,540
$8,903 139,103 $3,572 346 $516 - $902 - $8,903
139,103
kWh
$3,572
346
kW-months/year
$516
-
$
$902
-
$
TOTAL IMPLEMENTED Savings:
$13,458
Cost:
$35,883
$8,545 133,509 $3,546 344 $488 - $879 - $8,545
133,509
kWh
$3,546
344
kW-months/year
$488
-
$
$879
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $