Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2019 |
Principal Product | Engineering Fabrication |
NAICS | 333517 - Machine Tool Manufacturing |
SIC | 3542 - Machine Tools, Metal Forming Types |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 262,000 Units |
Production Hrs. Annual | 4,420 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $94,302 | 1,758,672 | kWh | $0.05 |
Electricity Demand | $38,899 | 6,210 | kW-months/year | $6.26 |
Electricity Fees | $4,889 | - | $ | - |
Natural Gas | $69,765 | 12,921 | MMBtu | $5.40 |
TOTAL ENERGY COSTS | $207,854 | |||
RECOMMENDED SAVINGS* | $30,401 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,501 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,790 Cost: - |
$2,790 | 52,652 | - | - | - | - | - | - |
$2,790 52,652 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $11,804 Cost: - |
$7,192 | 135,694 | $4,612 | 737 | - | - | - | - |
$7,192 135,694 kWh |
$4,612 737 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $519 Cost: $200 |
- | - | - | - | $519 | 96 | - | - |
- - kWh |
- - kW-months/year |
$519 96 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $916 Cost: $470 |
$916 | 17,280 | - | - | - | - | - | - |
$916 17,280 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7314 REDUCE VENTILATION AIR |
Savings: $660 Cost: $925 |
$265 | 4,999 | - | - | $395 | 73 | - | - |
$265 4,999 kWh |
- - kW-months/year |
$395 73 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $192 Cost: $290 |
$44 | 824 | $7 | 1 | - | - | $141 | - |
$44 824 kWh |
$7 1 kW-months/year |
- - MMBtu |
$141 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,625 Cost: $4,006 |
$1,625 | 30,656 | - | - | - | - | - | - |
$1,625 30,656 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $167 Cost: $412 |
$167 | 3,157 | - | - | - | - | - | - |
$167 3,157 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,728 Cost: $30,695 |
$7,429 | 140,172 | $2,429 | 388 | - | - | $1,870 | - |
$7,429 140,172 kWh |
$2,429 388 kW-months/year |
- - MMBtu |
$1,870 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $30,401 Cost: $36,998 |
$20,428 | 385,434 | $7,048 | 1,126 | $914 | 169 | $2,011 | - | $20,428 385,434 kWh |
$7,048 1,126 kW-months/year |
$914 169 MMBtu |
$2,011 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,501 Cost: $490 |
$2,834 | 53,476 | $7 | 1 | $519 | 96 | $141 | - | $2,834 53,476 kWh |
$7 1 kW-months/year |
$519 96 MMBtu |
$141 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |