Select a Center

Arizona State University
Boise State University
Case Western Reserve University
Clemson University
Colorado State University
Georgia Institute of Technology
Indiana University-Purdue University
Lehigh University
Louisiana State University
North Carolina State
Oklahoma State University
Oregon State University
San Diego State University
San Francisco State University
Syracuse University
Tennessee Technological University
Texas A&M, College Station
University of Alabama
University of Dayton
University of Delaware
University of Florida
University of Illinois, Chicago
University of Kentucky
University of Massachusetts
University of Miami
University of Missouri-Columbia
University of Nebraska–Lincoln
University of Texas Rio Grande Valley
University of Utah
University of Wisconsin, Milwaukee
West Virginia University
IAC logo
IAC Assessment: SU0498
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: SU0498
IAC Center Syracuse University
Assessment Year
Principal Product Actuators, Valves, Bottles
NAICS 336419 - Other Guided Missile and Space Vehicle Parts and Auxiliary Equipment Manufacturing
SIC 3568 - Power Transmission Equipment, Nec
Sales $204,000,000
# of Employees 200
Plant Area (Sq.Ft.) 100,000
Annual Production 150,000 Units
Production Hrs. Annual 4,208
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $95,842 4,613,938 kWh $0.02
Electricity Demand $75,207 10,425 kW/month $7.21
Electricity Fees $14,598 - $ -
Natural Gas $7,781 1,216 MMBtu $6.40
TOTAL ENERGY COSTS $204,410
RECOMMENDED SAVINGS* $35,884 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost One-time Revenue or Avoided Cost
$ kWh $ kW/month $ MMBtu $ $ $ $ $ $
01: 2.7314 REDUCE VENTILATION AIR Savings:
$6,925
Cost:
$882
$1,180 56,254 - - $5,745 896 - - - - - - $1,180
56,254
kWh
-
-
kW/month
$5,745
896
MMBtu
-
-
$
-
-
$
-
-
$
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$325
Cost:
$60
$176 8,400 $379 53 $(-230) (-36) - - - - - - $176
8,400
kWh
$379
53
kW/month
$(-230)
(-36)
MMBtu
-
-
$
-
-
$
-
-
$
03: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$22,525
Cost:
$4,900
$(-179) (-8,545) $(-1,221) (-170) - - - - $23,925 - - - $(-179)
(-8,545)
kWh
$(-1,221)
(-170)
kW/month
-
-
MMBtu
-
-
$
$23,925
-
$
-
-
$
04: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$346
Cost:
$85
- - - - $346 54 - - - - - - -
-
kWh
-
-
kW/month
$346
54
MMBtu
-
-
$
-
-
$
-
-
$
05: 2.7122 DISCONNECT BALLASTS Savings:
$81
Cost:
$30
$41 1,952 $40 6 - - - - - - - - $41
1,952
kWh
$40
6
kW/month
-
-
MMBtu
-
-
$
-
-
$
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$323
Cost:
$427
$89 4,231 $42 6 - - $111 - - - $81 - $89
4,231
kWh
$42
6
kW/month
-
-
MMBtu
$111
-
$
-
-
$
$81
-
$
07: 2.7134 USE PHOTOCELL CONTROLS Savings:
$380
Cost:
$615
$380 18,116 - - - - - - - - - - $380
18,116
kWh
-
-
kW/month
-
-
MMBtu
-
-
$
-
-
$
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,979
Cost:
$18,397
$2,504 119,221 $2,459 341 - - - - - - $16 - $2,504
119,221
kWh
$2,459
341
kW/month
-
-
MMBtu
-
-
$
-
-
$
$16
-
$
TOTAL RECOMMENDED Savings:
$35,884
Cost:
$25,396
$4,191 199,629 $1,699 235 $5,861 914 $111 - $23,925 - $97 - $4,191
199,629
kWh
$1,699
235
kW/month
$5,861
914
MMBtu
$111
-
$
$23,925
-
$
$97
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - - - -
-
kWh
-
-
kW/month
-
-
MMBtu
-
-
$
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW/month $ MMBtu $ $ $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost One-time Revenue or Avoided Cost