Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2020 |
Principal Product | Vision and Multisensor Measuring Machines |
NAICS | 333314 - Optical Instrument and Lens Manufacturing |
SIC | 3827 - Optical Instruments And Lenses |
Sales | $10,000,000-$50,000,000 |
# of Employees | 320 |
Plant Area (Sq.Ft.) | 181,200 |
Annual Production | 25,000 Units |
Production Hrs. Annual | 2,340 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $106,673 | 2,918,067 | kWh | $0.04 |
Electricity Demand | $151,087 | 12,103 | kW-months/year | $12.48 |
Electricity Fees | $25,772 | - | $ | - |
Natural Gas | $36,984 | 6,045 | MMBtu | $6.12 |
TOTAL ENERGY COSTS | $362,696 | |||
RECOMMENDED SAVINGS* | $35,752 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,125 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $7,584 Cost: $534 |
$3,496 | 94,500 | $6,553 | 525 | $(-2,465) | (-403) | - | - | - | - |
$3,496 94,500 kWh |
$6,553 525 kW-months/year |
$(-2,465) (-403) MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7314 REDUCE VENTILATION AIR |
Savings: $2,636 Cost: $882 |
$732 | 19,797 | - | - | $1,904 | 311 | - | - | - | - |
$732 19,797 kWh |
- - kW-months/year |
$1,904 311 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,448 Cost: $4,525 |
$667 | 18,036 | $307 | 25 | - | - | $977 | - | $496 | - |
$667 18,036 kWh |
$307 25 kW-months/year |
- - MMBtu |
$977 - $ |
$496 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $627 Cost: $999 |
$627 | 16,946 | - | - | - | - | - | - | - | - |
$627 16,946 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $6,889 Cost: $11,879 |
$(-171) | (-4,620) | $(-4,925) | (-396) | - | - | - | - | $11,985 | - |
$(-171) (-4,620) kWh |
$(-4,925) (-396) kW-months/year |
- - MMBtu |
- - $ |
$11,985 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,223 Cost: $75,235 |
$5,119 | 138,346 | $9,372 | 751 | - | - | $657 | - | $75 | - |
$5,119 138,346 kWh |
$9,372 751 kW-months/year |
- - MMBtu |
$657 - $ |
$75 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $345 Cost: $64 |
$345 | 9,330 | - | - | - | - | - | - | - | - |
$345 9,330 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,752 Cost: $94,118 |
$10,816 | 292,335 | $11,307 | 905 | $(-561) | (-92) | $1,634 | - | $12,556 | - | $10,816 292,335 kWh |
$11,307 905 kW-months/year |
$(-561) (-92) MMBtu |
$1,634 - $ |
$12,556 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,125 Cost: $93,119 |
$10,189 | 275,389 | $11,307 | 905 | $(-561) | (-92) | $1,634 | - | $12,556 | - | $10,189 275,389 kWh |
$11,307 905 kW-months/year |
$(-561) (-92) MMBtu |
$1,634 - $ |
$12,556 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |