Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2023 |
Principal Product | Contract Metal Fabricator |
NAICS | 332322 - Sheet Metal Work Manufacturing |
SIC | 3444 - Sheet Metalwork |
Sales | $50,000,000-$100,000,000 |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 135,000 |
Annual Production | 2,600,000 Units |
Production Hrs. Annual | 6,400 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $193,521 | 1,961,131 | kWh | $0.10 |
Electricity Demand | $76,975 | 7,086 | kW-months/year | $10.86 |
Natural Gas | $62,547 | 12,801 | MMBtu | $4.89 |
TOTAL ENERGY COSTS | $362,258 | |||
RECOMMENDED SAVINGS* | $61,592 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $669 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $9,727 Cost: $45 |
- | - | - | - | - | - | $9,727 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$9,727 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $1,784 Cost: $45 |
- | - | - | - | - | - | $1,784 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,784 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7122 DISCONNECT BALLASTS |
Savings: $104 Cost: - |
$81 | 815 | $23 | 2 | - | - | - | - |
$81 815 kWh |
$23 2 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $576 Cost: - |
$576 | 5,818 | - | - | - | - | - | - |
$576 5,818 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $159 Cost: - |
$159 | 1,606 | - | - | - | - | - | - |
$159 1,606 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,870 Cost: $113 |
$1,337 | 13,500 | $815 | 75 | $(-281) | (-58) | - | - |
$1,337 13,500 kWh |
$815 75 kW-months/year |
$(-281) (-58) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $669 Cost: $83 |
$163 | 1,642 | $25 | 2 | - | - | $482 | - |
$163 1,642 kWh |
$25 2 kW-months/year |
- - MMBtu |
$482 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,364 Cost: $413 |
$1,364 | 13,775 | - | - | - | - | - | - |
$1,364 13,775 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $27,713 Cost: $29,395 |
$27,713 | 279,930 | - | - | - | - | - | - |
$27,713 279,930 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $924 Cost: $1,011 |
$924 | 9,330 | - | - | - | - | - | - |
$924 9,330 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.8227 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION |
Savings: $16,546 Cost: $21,000 |
$(-6,064) | (-61,250) | - | - | - | - | $22,610 | - |
$(-6,064) (-61,250) kWh |
- - kW-months/year |
- - MMBtu |
$22,610 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $111 Cost: $185 |
$111 | 1,121 | - | - | - | - | - | - |
$111 1,121 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $46 Cost: $198 |
- | - | - | - | $46 | 9 | - | - |
- - kWh |
- - kW-months/year |
$46 9 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $61,592 Cost: $52,488 |
$26,363 | 266,288 | $862 | 79 | $(-235) | (-48) | $34,602 | - | $26,363 266,288 kWh |
$862 79 kW-months/year |
$(-235) (-48) MMBtu |
$34,602 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $669 Cost: $83 |
$163 | 1,642 | $25 | 2 | - | - | $482 | - | $163 1,642 kWh |
$25 2 kW-months/year |
- - MMBtu |
$482 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |