Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1982
Principal Product HOSPITAL FOOD EQUIPMENT
NAICS n/a
SIC 3589 - Service Industry Machinery, Nec
Sales $5,000,000-$10,000,000
# of Employees 85
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 2,250
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $47,392 1,048,945 kWh $0.05
Natural Gas $11,228 3,594 MMBtu $3.12
TOTAL ENERGY COSTS $58,620
RECOMMENDED SAVINGS* $5,121 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$594
Cost:
$600
$594 10,551 - - $594
10,551
kWh
-
-
MMBtu
02: 2.7245 USE DIRECT AIR SUPPLY TO EXHAUST HOODS Savings:
$1,363
Cost:
$305
$208 8,792 $1,155 370 $208
8,792
kWh
$1,155
370
MMBtu
03: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$3,164
Cost:
$8,376
$1,228 27,257 $1,936 620 $1,228
27,257
kWh
$1,936
620
MMBtu
TOTAL RECOMMENDED Savings:
$5,121
Cost:
$9,281
$2,030 46,600 $3,091 990 $2,030
46,600
kWh
$3,091
990
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas