Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1982
Principal Product TIMERS
NAICS n/a
SIC 3625 - Relays And Industrial Controls
Sales n/a
# of Employees 200
Plant Area (Sq.Ft.) 0
Annual Production 1,000,000 Pieces
Production Hrs. Annual 4,000
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $121,535 3,072,099 kWh $0.04
Natural Gas $13,925 3,302 MMBtu $4.22
TOTAL ENERGY COSTS $135,460
RECOMMENDED SAVINGS* $7,433 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,431
Cost:
$1,971
$2,431 61,547 - - $2,431
61,547
kWh
-
-
MMBtu
02: 2.2514 COVER OPEN TANKS Savings:
$2,342
Cost:
$400
$2,342 59,203 - - $2,342
59,203
kWh
-
-
MMBtu
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,660
Cost:
$4,250
- - $2,660 631 -
-
kWh
$2,660
631
MMBtu
TOTAL RECOMMENDED Savings:
$7,433
Cost:
$6,621
$4,773 120,750 $2,660 631 $4,773
120,750
kWh
$2,660
631
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas