Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1983
Principal Product CRUSHED ROCK AND SAND
NAICS n/a
SIC 3281 - Cut Stone And Stone Products
Sales $1,000,000-$5,000,000
# of Employees 27
Plant Area (Sq.Ft.) 0
Annual Production 269,280 Tons
Production Hrs. Annual 2,080
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $180,971 2,417,057 kWh $0.07
TOTAL ENERGY COSTS $180,971
RECOMMENDED SAVINGS* $(-12,595) *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION Savings:
$(-14,400)
Cost:
$10,000
$9,900 - $(-24,300) - $9,900
-
kWh
$(-24,300)
-
$
02: 2.6122 ADJUST VENTS TO MINIMIZE ENERGY USE Savings:
$1,540
Cost:
-
$1,540 30,774 - - $1,540
30,774
kWh
-
-
$
03: 2.5121 REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH Savings:
$265
Cost:
-
$265 5,275 - - $265
5,275
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$(-12,595)
Cost:
$10,000
$11,705 36,049 $(-24,300) - $11,705
36,049
kWh
$(-24,300)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Administrative Changes Electricity Usage Administrative Changes