IAC logo
IAC Assessment: TN0304
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TN0304
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1987
Principal Product PLASTIC FURNITURE
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 0
Annual Production 10,000,000 Pieces
Production Hrs. Annual 6,000
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $313,182 6,065,065 kWh $0.05
Natural Gas $17,755 3,534 MMBtu $5.02
TOTAL ENERGY COSTS $330,937
RECOMMENDED SAVINGS* $30,189 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $17,619
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2511 INSULATE BARE EQUIPMENT Savings:
$10,943
Cost:
$650
$10,943 210,434 - - $10,943
210,434
kWh
-
-
MMBtu
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$2,510
Cost:
$2,700
- - $2,510 502 -
-
kWh
$2,510
502
MMBtu
03: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$6,630
Cost:
$12,000
$6,630 127,491 - - $6,630
127,491
kWh
-
-
MMBtu
04: 2.6232 INSTALL SET-BACK TIMERS Savings:
$4,039
Cost:
-
$4,039 77,667 - - $4,039
77,667
kWh
-
-
MMBtu
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$2,637
Cost:
$2,680
$2,637 50,703 - - $2,637
50,703
kWh
-
-
MMBtu
06: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$1,707
Cost:
-
$1,707 32,825 - - $1,707
32,825
kWh
-
-
MMBtu
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,174
Cost:
-
$1,174 22,567 - - $1,174
22,567
kWh
-
-
MMBtu
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$549
Cost:
$94
$549 10,551 - - $549
10,551
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$30,189
Cost:
$18,124
$27,679 532,238 $2,510 502 $27,679
532,238
kWh
$2,510
502
MMBtu
TOTAL IMPLEMENTED Savings:
$17,619
Cost:
$3,330
$17,619 338,804 - - $17,619
338,804
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas